3-6. The adjustment item which in necessary in part exchange
COMPL PWB CP1
COMPL PWB ST1
COMPL PWB ST2
ASSY FPC, CA1
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
3-7. Updating the firmware
Check the firmware version immediately after the CP1 board has been replaced. If an old version is being used, interfer-
ence and errors in operation may also occur. If an old version is being used, update it with a newer version.
3-13. Firmware uploading procedure. (Page 21)
Refer to
3-8. Adjust Specifications
1. Lens Adjustment (Infinity)
Camera
Preparation:
POWER switch: ON
If using a ready-made collimator, set to infinity.
Note:
Do not vibrate during the adjustment.
If readjusting after it has already been adjusted, wait for 15
minutes or more for the unit to cool down first.
Lens
AWB
Adjust-
Adjust-
ment
ment
(Infinity)
Collimator
CCD Black
CCD White
Point And
Point
White Point
Defect
Defect
Detect
Detect
Adjustment
Adjustment
In Lighted
Adjustment method:
1. Set a distance of 0.5-1.0 cm between camera lens and
collimator lens (zoom wide position) . Do not touch the
each lens.
2. Set the camera so that it becomes center of the screen in
the collimator.
3. Double-click on the DscCalDi.exe.
4. Select "Infinity Cal." on the LCD "Test", and click the "Yes".
5. Lens infinity adjustment value will appear on the screen.
6. Click the OK.
Dsc Calibration
-
-
18
USB
Factory
Language
storage
Cord
Setting
information
Setting
registration
x
Focus Result
PZ_SW_A_B: 956
PZ_SW_B_C: 1058
PZ_SW_C_B: 1037
PZ_BR: 17
PZ_SP: 266
AF_SW: 941
AF_BR: 6
AF_WIDE: 1
AF_MID1: -19
AF_MID2: -37
AF_MID3: -36
AF_TELE: -33
OK
Reset
Setting