3-2-14. No Power-IC6016(1.1V DDCON) Checking Procedure
Start
No
Check voltage at
JL6035(BBA/BBE).
1.09V-1.11V?
Yes
End
Refer IC6010
Checking Procedure'
No
Yes
Check CL6037(BBA/BBE)
3.267V-3.333V?
TV in stand-by mode
or MTK damage.
No
Yes
Check CL6008 (BBA/BBE)
3.00V-3.33V?
OK
Replace IC6016
& check again at
Yes
IC6016 damage.
JL6035
(BBA/BBE).
1.09V-1.11V?
No
Check JL6035
(BBA/BBE) by
Continuity Test.
OK or short?
Short
Check & remove any
No
foreign material
Foreign material
attach to the board.
Still shorted?
Short
Refer Beryls
Checking
Procedure
50