Sanyo SAP–KM97AHA Technical & Service Manual page 17

Multi-split system air conditioner
Table of Contents

Advertisement

Indoor Unit A
Indoor Unit B
Insulation of Refrigerant Tubing
IMPORTANT
Because capillary tubing is used in the outdoor unit, both the
wide and narrow tubes of this air conditioner become cold. To
prevent heat loss and wet floors due to dripping of condensa-
tion, both tubes must be well insulated with a proper insulation
material. The thickness of the insulation should be a min. 8
mm.
CAUTION
Wide tube
O.D.
9.52mm
(3/8")
Narrow tube
O.D.
6.35mm
(1/4")
Wide tube
O.D.
9.52mm
(3/8")
Narrow tube
O.D.
6.35mm
(1/4")
After a tube has been insulated,
never try to bend it into a narrow
curve because it can cause the tube
to break or crack.
Accumulator
Muffler
Check
port
Strainer
Capillary
tube
Accumulator
Muffler
Check
port
Strainer
Thickness:
Min. 8 mm
Wide tube
13
Compressor A
4 – Way
valve
Check valve
Drier
(
)
Compressor B
4 – Way
valve
Check valve
Drier
(
)
Capillary tube
Wide Tube Service valve
Narrow Tube Service valve
Insulation
Narrow tube
Thickness:
Min. 8 mm