MULTIQUIP DLW400ESA4 Operation Manuals page 36

Welder/generator (kubota d902e4bwdde2 diesel engine)
Table of Contents

Advertisement

SINGLE MODE WELDING (CC)
1. Place the welding mode selector switch (Figure 29) in
the single mode position.
Figure 29. Single-Dual Selector Switch
(Single Position)
2. For CC welding, place the welding mode rocker switch
in the CC position (down).
Figure 30. Welding Mode Switch (CC Mode)
3. Place e-Mode selector switch (Figure 31) in the
desired position as defined by Table 19. This switch is
a 3-position rocker switch.
Figure 31. E-Mode Selector Switch (CC Mode)
PAGE 36 — DLW400ESA4 WELDER/GENERATOR • OPERATION MANUAL — REV. #0 (03/14/18)
Table 19. Current Range/Engine Speed
(Single Mode Operation)
e Mode
Low
Selector
2300 rpm
Switch
Variable/
30~200A
Low
See Notes
High/Low
See Notes
High
Note 1: If using two welders connected with different polartities to weld the same
work, the voltage between the holders may cause electric shock to the
operator.
Note 2: If using two welders connected with different polartities to weld the same
work, use separate grounds for each welder.
Note 3: NEVER switch the Single-Dual Selector Switch during welding operations.
Switch contacting failure may occur.
NOTICE
If the welding work requires a current of 240 amps or less
for single mode applications, place the e-mode selector
switch in the high/low or high position if bead appearance
or welding faults are a concern.
In addition, place the e-mode selector switch in the high
position if an AC load of 100 watts or an AC load with a
magnet switch is used.
4. If welding is started with the e-mode selector switch
in the variable/low position, the standard welding load
voltage is automatically calculated based on the preset
welding current (Figure 32) and the engine speed will
be controlled by the available kW capacity of the unit
for either single or dual mode operation.
The engine will then be placed into low-speed operation
about 9~10 seconds after a pause of welding work.
3800
3600
3400
3200
3000
2800
2600
4mm Single
Ø
(~200A)
2400
2200
2000
0
2000
4000
Figure 32. E-Mode Engine Variable Control
OPERATION
Variable
High
2300~3600 rpm
3600 rpm
200~400A
See Notes
30~400A
30~400A
See Notes
4mm Dual
Ø
(160Ax2)
3.2mm Dual
Ø
(140Ax2)
6000
8000
10000
Preset Welding (kW)
12000

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents