Onkyo TX-NR525 Service Manual page 18

Black and silver models
Hide thumbs Also See for TX-NR525:
Table of Contents

Advertisement

OPERATION CHECK-5
2.TEST MODE(3/4)
2-2. TEST MODE FOR OPERATION(Continue)
Auto Measurement Mode
[Note] Do not connect the loudspeaker.
TEST
DSP Output ch
No.
4-00
ALL
4-01
ALL
4-02
ALL
4-03
SW
4-04
FL,FR
4-05
FR,C,SL,SR,SBL,SBR,SW
4-06
FL,C,SL,SR,SBL,SBR,SW
4-07
FL,FR,SL,SR,SBL,SBR,SW
4-08
FL,FR,C,SR,SBL,SBR,SW
4-09
FL,FR,C,SL,SBL,SBR,SW
4-10
FL,FR,C,SL,SR,SBR,SW
4-11
FL,FR,C,SL,SR,SBL,SW
4-12
FL,FR,C,SL,SR,SBL,SBR
4-13
ALL
4-14
ALL
4-15
ALL
4-16
ALL
4-21
FL
4-22
FR
4-23
C
4-24
SL
4-25
SR
4-26
SBL
4-27
SBR
4-28
FL
4-29
FR
4-30
C
4-31
SL
4-32
SR
4-33
SBL
4-34
SBR
4-35
ALL
4-36
"FL,FR,C,SL,SR"
4-37
C,SL,SR,SBL,SBR
4-38
ALL
4-39
ALL
4-40
ALL
In all test modes, it is not concerned with detection of VOLH but SEC1H are made "H" fixation. (Except TEST4-36 and 4-37.)
*1: All SP-RELAYs are turned ON only at the time of this STEP.
Moreover, whether make RELAY restoration time at the time of protection operation into 1 second, and PROTECT input "H"
is detected how many times or it continues 1 second or more, RELAY is not held at OFF or POWER OFF is not carried out,
either.
When "H" is 1 seconds or more to PROTECT input and it is set to "L", RELAY is turned ON again.
Moreover, not any MUTE is outputted at the time of this STEP.
*3 : When TEST No. 4-21
*4 : The following signal is putted out at all channel continuously in TEST4-35
2 mS 2 mS
*5 : VOLH is detected and H/L of SEC1H is changed.
A detection level is the same as the normal mode.
When it is detected, light "FM STEREO" on FL TUBE.
*6 : SBL/SBR correspond only HT-R592.
DSP Output
DSP
CConfig.
Frequency
Output
Voltage
1kHz
-20dBFS
Y/L/L/L/L
30Hz
-20dBFS
Y/L/L/L/L
20kHz
-20dBFS
Y/L/L/L/L
30Hz
-20dBFS
N/L/L/L/L
30Hz
-20dBFS
N/L/L/L/L
10kHz
-20dBFS
Y/L/L/L/L
10kHz
-20dBFS
Y/L/L/L/L
10kHz
-20dBFS
Y/L/L/L/L
10kHz
-20dBFS
Y/L/L/L/L
10kHz
-20dBFS
Y/L/L/L/L
10kHz
-20dBFS
Y/L/L/L/L
10kHz
-20dBFS
Y/L/L/L/L
30Hz
-20dBFS
Y/L/L/L/L
1kHz
-20dBFS
Y/L/L/L/L
30Hz
-20dBFS
Y/L/L/L/L
1kHz
-20dBFS
Y/L/L/L/L
30Hz
-20dBFS
Y/L/L/L/L
+DC
+Max
Y/L/L/L/L
-DC
-Max
Y/L/L/L/L
+DC
+Max
Y/L/L/L/L
-DC
-Max
Y/L/L/L/L
+DC
+Max
Y/L/L/L/L
-DC
-Max
Y/L/L/L/L
+DC
+Max
Y/L/L/L/L
-DC
-Max
Y/L/L/L/L
+DC
+Max
Y/L/L/L/L
-DC
-Max
Y/L/L/L/L
+DC
+Max
Y/L/L/L/L
-DC
-Max
Y/L/L/L/L
+DC
+Max
Y/L/L/L/L
-DC
-Max
Y/L/L/L/L
Pulse
Max
Y/L/L/L/L
1kHz
0dBFS
Y/L/L/L/L
1kHz
0dBFS
Y/L/L/L/L
1kHz
-20dBFS
Y/L/L/L/L
30Hz
-20dBFS
Y/L/L/L/L
20kHz
-20dBFS
Y/L/L/L/L
34 is setted, DC votage is putted out immediately at each channel. (within 100msec.)
20 mS
TX-NR525/HT-R592/HT-RC550
Master Vol.
Speaker
etc.
Relay
64(-16dB)
F/CS/SB
64(-16dB)
F/CS/SB
64(-16dB)
F/CS/SB
58(-22dB)
F/CS/SB
64(-16dB)
F/CS/SB
64(-16dB)
F/CS/SB
Mute:FL
64(-16dB)
F/CS/SB
Mute:FR
64(-16dB)
F/CS/SB
Mute:C
64(-16dB)
F/CS/SB
Mute:SL
64(-16dB)
F/CS/SB
Mute:SR
64(-16dB)
F/CS/SB
Mute:SBL *6
64(-16dB)
F/CS/SB
Mute:SBR *6
64(-16dB)
F/CS/SB
Mute:SW
64(-16dB)
F/CS/SB
*mut on
64(-16dB)
F/CS/SB
*mut on
Min(-80dB)
F/CS/SB
Min(-80dB)
F/CS/SB
Max
F/CS/SB
*1,*3
Max
F/CS/SB
*1,*3
Max
F/CS/SB
*1,*3
Max
F/CS/SB
*1,*3
Max
F/CS/SB
*1,*3
Max
F/CS/SB
*1,*3,*6
Max
F/CS/SB
*1,*3,*6
Max
F/CS/SB
*1,*3
Max
F/CS/SB
*1,*3
Max
F/CS/SB
*1,*3
Max
F/CS/SB
*1,*3
Max
F/CS/SB
*1,*3
Max
F/CS/SB
*1,*3,*6
Max
F/CS/SB
*1,*3,*6
58(-22dB)
F/CS/SB
*1,*4
55(-25dB)
F/CS/SB
vol=55
55(-25dB)
F/CS/SB
*5,*6
59(-21dB)
F/CS/SB
59(-21dB)
F/CS/SB
59(-21dB)
F/CS/SB
Max
Max
DSP Gain
DSP Freq.Response
DSP Freq.Response
Characteristic(1)
Characteristic(2)
Separation
Separation
Separation
Separation
Separation
Separation
Separation
Separation
Muting
Muting
Volume Max.Attenuation
Volume Max.Attenuation
+DC Protect
-DC Protect
+DC Protect
-DC Protect
+DC Protect
-DC Protect
+DC Protect
-DC Protect
+DC Protect
-DC Protect
+DC Protect
-DC Protect
+DC Protect
-DC Protect
Current Protect
VOLH DET
VOLH DET
IDLING TIMER

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tx-nr525bTx-nr525s

Table of Contents