Warranty Options - Lenovo IBM System x3620 M3 Product Manual

2u, dual-socket rack server
Table of Contents

Advertisement

Physical and electrical specifications
Dimensions:
Width: 488 mm (19.2 in)
Depth: 749 mm (29.5 in)
Height: 87 mm (3.4 in)
Weight:
Minimum configuration: 16.30 kg (35.94 lb)
Maximum configuration: 22.45 kg (49.50 lb)
Operating environment:
Air temperature
Server on
10 - 35 C (50 - 95 F); altitude: 0 - 915 m (3,000 ft)
10 - 32 C (50 - 95 F); altitude: 915 - 2134 m (3,000 - 7,000 ft)
10 - 28 C (50 - 83 F); altitude: 2134 - 3050 m (7,000 - 10,000 ft)
Server off: 5 - 45 C (41 F - 113 F)
Shipment: -40 C to +60 C (-40 F to 140 F)
Humidity
Server on: 20 - 80%, maximum dew point 21 C, maximum rate of change 5 C/hr
Server off: 8 - 80%, maximum dew point 27 C
Shipment: 5 - 100%
Electrical:
Models with 675 W power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 7.8 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 3.8 A
Input kilovolt-amperes (kVA) (approximately):
Models with 460 W power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 5.3 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 2.6 A
Input kilovolt-amperes (kVA) (approximately):
BTU output
Minimum configuration: 307 Btu/hr (90 watts)
Maximum configuration: 2662 Btu/hr (780 watts)
Acoustical noise level emission level: Sound power levels
6.1 bels (idling)
6.1 bels (operating)

Warranty options

IBM System x3620 M3 (Withdrawn)
Minimum configuration: 0.12 kVA
Maximum configuration: 0.78 kVA
Minimum configuration: 0.12 kVA
Maximum configuration: 0.53 kVA
23

Advertisement

Table of Contents
loading

Table of Contents