Mitsubishi Electric FR-A7AZ Instruction Manual page 16

700 series bipolar analog output function high resolution analog input function motor thermistor interface
Table of Contents

Advertisement

REMARKS
• Information on blade terminals
Commercially available product examples (as of January 2010)
Cable Size
Terminal
Screw Size
(mm
M2
0.3, 0.5
Blade terminal crimping tool: CRIMPFOX 6T-F/6 (Phoenix Contact Co., Ltd.)
Insert wires to a blade terminal, and check that the wires come out for about 0 to 0.5 mm from the sleeve.
Check the condition of the blade terminal after crimping. Do not use a blade terminal of which the crimping is
inappropriate, or the face is damaged.
CAUTION
The wiring length should be 30m maximum.
Blade Terminal Model
2
With insulation sleeve
)
AI 0,5-6WH
Damaged
INSTALLATION AND WIRING
Without insulation sleeve
A 0,5-6
Unstranded
wires
Wires are not inserted
into the shell
Crumpled tip
Manufacturer
Phoenix Contact
Co.,Ltd.
11