Cisco 5915 Technical Manual page 13

Embedded services router
Table of Contents

Advertisement

Table 7
Cisco 5915 ESR Feature
Operating temperature
Non-Operating Temperature
Altitude (low-pressure
operation)
EMI/EMC
Hardware Specifications
Power requirements/profile
OL-24796-01
Cisco 5915 ESR Product Specifications (continued)
Feature Description
The conduction-cooled router can withstand extended
temperature ranges of -40ºF to +185ºF (–40ºC to +85ºC).
Note
The air-cooled router can withstand extended temperature
ranges of -40ºF to +158ºF (–40ºC to +70ºC).
Temperature ranges for completed solutions depend on
hardware configuration variables, including enclosures and
third-party components.
-40ºF to +185ºF (-40ºC to +85ºC) for both the air-cooled and
conduction cooled boards
Up to 15,000 ft. (4500 m) for both the air-cooled and
conduction-cooled boards
Conforms to CISPR 22, FCC Part15B Class A limits
The system integrator is responsible for completing the
necessary Safety/EMC testing and labelling the final product
sold to the customer.
5 VDC from PCI connector (5V)
Max (theoretical)
Typical (rail temperature @ 25C)
Typical (rail temperature @ 85C):
InRush:
3.3 VDC from PCI connector (3.3V)
Max (theoretical):
Typical (rail temperature @ 25C)
Typical (rail temperature @ 85C):
InRush:
Total
Max (theoretical):
Typical (rail temperature @ 25C)
Typical (rail temperature @ 85C):
Note
Cisco 5915 Embedded Services Router Hardware Technical Guide
Temperatures are measured at card edge rail. Card edge rail
must be 85º Celsius or lower.
:
4.26W
1.25A
5.93W
1.32A
10.19W
There are no voltage rail sequencing requirements. Power
supply voltage rails can power-up/power-down in any order.
Both the 3.3V and 5V rails are required for the Cisco 5915
ESR.
Product Specifications
1
:
3.00W
1
3.10W
1
:
2.64W
1
3.06W
1
:
5.64W
1
6.14W
13