Fltwrn - Canon WX6000 User Commands

Hide thumbs Also See for WX6000:
Table of Contents

Advertisement

FLTWRN

Filter warning indication at startup
Format
FLTWRN=<Filter warning parameter: ID>
GET□FLTWRN
/
?△FLTWRN
<Filter warning parameter: ID>
OFF
ON
Environment
Power
OFF
ON
PM
D-RGB
X
O
X
Response
"i:OK" is returned when setting of filter warning indication at startup was completed successfully.
For '
' or '
GET FLTWRN
?FLTWRN
'g:FLTWRN=<Filter warning parameter: ID>'
For details on other responses, refer to the "Error List".
Description
(1)
This command is used to set the indication of filter warning at startup.
(2)
This command functions in the same way as when "Installation setting" - "On screen" -
"Filter warning indication" are selected on the menu.
(3)
The current setting of filter warning indication at startup can be obtained using the GET
command. ("
GET FLTWRN
(4)
The setting of Filter warning indication at startup retains the last setting after the power is
turned off.
Example
Setting
> FLTWRN=OFF
< i:OK
Reference
> GET FLTWRN or ?FLTWRN
< g:FLTWRN
*Commands are indicated by ">", and responses are indicated by "<".
Turned off
Turned on
Input
A-RGB
COMP
HDMI
None
-
', current setting of filter warning indication at startup is returned as
")
Filter warning indication at startup is disabled.
The setting of filter warning indication at startup is acquired.
- 41 -
WX6000 / SX6000 User Commands