Siemens sitrans LR 400 Instruction Manual And Users Manual page 92

Radar level sensor
Hide thumbs Also See for sitrans LR 400:
Table of Contents

Advertisement

Flange 22483 or 22488, FF Standard Process Seal*
-100
-50
Flange 22483 or 22488, RF Process Seal for Hazardous Locations**
-100
-50
* standard process seal is rated to a max. of 200 °C of continuous duty.
**process seal for hazardous location is rated to a max. of 250 °C of continuous duty.
WARNINGS:
• Materials of construction are chosen based on their chemical
compatibility (or inertness) for general purposes. For exposure to
specific environments, check with chemical compatibility charts before
installing.
• The user is responsible for the selection of bolting and gasket materials
which will fall within the limits of the flange and its intended use and
which are suitable for the service conditions.
• Never attempt to loosen, remove, or disassemble process connection or
instrument housing with vessel contents.
• Improper installation may result in loss of process pressure.
Page 91
30.0
25.0
20.0
15.0
10.0
5.0
0.0
0
50
100
Temperature (°C)
60.0
50.0
40.0
30.0
20.0
10.0
0.0
0
50
100
Temperature (°C)
SITRANS LR 400 – INSTRUCTION MANUAL
150
200
250
150
200
250
300
3", 4", 6"
300 #
3", 4", 6"
150 #
6", 300 #
3", 4", 6"
300 #
6", 300#
3", 4", 5"
300#
7ML19985FH04