Lincoln Electric DC-600 series Operator's Manual page 33

Multi-process welders
Table of Contents

Advertisement

E-5
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
Machine input contactor operates
but
machine
has
no
output.Fan runs and pilot light
glows.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
POSSIBLE
CAUSE
OUTPUT PROBLEMS
1. Place OUTPUT TERMINAL
weld
Switch to "ON", or install a
jumper from #2 to #4 on
machine terminal strip. If
machine
restored the problem is in the
wire feeder or control cable.
2. If remote control is not being
used
make
LOCAL/REMOTE SWITCH
(SW3) is in the "Local" position.
3. Check 42V Circuit Breaker in
the front panel.Reset if neces-
sary.
4. Check for loose or faulty weld
cable connections.
5. Trigger circuit not working.
CAUTION
DC-600
RECOMMENDED
COURSE OF ACTION
weld
output
is
certain
the
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.
E-5