17" LCD Color Monitor

6.1 Susceptibility of display to external environment

Operating
- Temperature
- Humidity
- Altitude
- Air pressure
Storage
- Temperature
- Humidity
- Altitude
- Air pressure
Note: recommend at 5 to 35°C, Humidity less than 60 %

6.2 Display disturbances from external environment

According to IEC 801-2 for ESD disturbances

6.3 Display disturbances to external environment

Refer to Safety requirement

7. Reliability

7.1 Mean Time Between Failures

System MTBF (Excluding the LCD panel and CCFL) : 50,000 hrs

8. Quality assurance requirements

8.1 Acceptance test

According to MIL-STD-105D
AQL: 0.4 (major) 1.5 (minor)
(Please also refer to annual quality agreement)
Customer acceptance criteria: UAW0377/00

9. Serviceability

The serviceability of this monitor should fulfill the requirements which are prescribed in UAW-0346 and must be
checked with the check list UAT-0361.
: 0 to 35 degree C
: 80% max
: 0-3658m
: 600-1100 mBAR
: -20 to 60 degree C
: 85% max ( < 40℃ )
: 0-12192m
: 300-1100 mBAR
Control II level