Trouble shooting 21
OUTDOOR UNIT Error Method:
3-Way Valve Thermistor Error
Detective Actuators:
Outdoor Unit Main PCB Circuit
3-way valve Temperature Thermistor
Forecast of Cause :
1. Connector connection failure 2.Thermistor failure 3. Main PCB failure
Check Point 1 : Check connection of Connector
Check if connector is removed.
Check erroneous connection.
Check if thermistor cable is open.
>>Upon correcting the removed connector or miss-wiring, reset the power.
OK
OK
Check Point 2 : Remove connector and check Thermistor resistance value
Thermistor Characteristics (Approx. value)
Temperature(°F)
Resistance Value (k )
Temperature(°F)
Resistance Value (k )
If Thermistor is either open or shorted, replace it and reset the power.
OK
OK
Check Point 3 : Check voltage of Main PCB (DC5.0V)
M
ake sure circuit diagram of outdoor unit and check terminal voltage at Thermistor (DC5.0V)
AOU18RLXFZH
VALVE THERMISTOR A, B
BLACK
1
1
1
WHITE
RED
3
2
2
WHITE
4
3
3
WHITE
YELLOW
4
5
4
CN39
WHITE
6
5
5
WHITE
WHITE
BLUE
7
6
6
WHITE
8
7
7
WHITE
BLACK
8
9
8
WHITE / WHITE
If the voltage does not appear, replace Main PCB.
Indicate or Display:
Outdoor Unit :
Indoor Unit
ERROR CODE : [E : 76]
Detective details:
When 3-way valve Temperature Thermistor open or short-circuit is
detected at power ON or while running the compressor.
14°F
23°F
32°F
312
233
176
104°F
122°F
140°F
25.6
17.1
11.6
2-WAY VALVE A
3-WAY VALVE A
2-WAY VALVE B
3-WAY VALVE B
LED 1 : 6 time Flash (for Indoor unit A)
LED 2 : 6 time Flash (for Indoor unit B)
LED 3 : 6 time Flash (for Indoor unit C)
: Operation lamp: 7 time Flash, Timer lamp: 6 time Flash
Economy lamp: Continuous flash.
41°F
50°F
59°F
134
103
80.3
158°F
176°F
194°F
8.12
5.78
4.19
AOU24RLXFZH
VALVE THERMISTOR A
BLACK
BLACK
1
1
1
WHITE
RED
3
2
2
WHITE
4
3
3
WHITE
YELLOW
4
5
4
CN39
WHITE
6
5
5
WHITE
WHITE
BLUE
7
6
6
WHITE
8
7
7
WHITE
BLACK
8
9
8
WHITE / WHITE
VALVE THERMISTOR C
BLACK
BLACK
1
1
1
1
RED
GRAY
2
2
2
RED
4
4
3
3
RED
BROWN
5
5
4
4
C
CN40
RED
6
6
5
5
WHITE
RED
6
6
6
7
7
RED
7
8
8
7
RED
9
9
8
8
WHITE / RED
02-26
68°F
86°F
62.9
39.6
212°F
3.09
, B
2-WAY VALVE A
2-WAY VALVE A
3-WAY VALVE A
3-WAY VALVE A
2-WAY VALVE B
2-WAY VALVE B
3-WAY VALVE B
3-WAY VALVE B
2-WAY VALVE
2-WAY VALVE C
3-WAY VALVE
3-WAY VALVE C