T
ECHNICAL DATA
Model
Inverter
Nominal battery voltage
Input voltage range
Continuous power @ 25°C
Power 30 min. @ 25°C
Power 5 min. @ 25°C
Power 5 sec. @ 25°C
Maximum asymmetric load
Max. efficiency (%)
Cos φ max.
Detection of the load
Current of short-circuit 2 sec. (exit)
Output voltage
Frequency
Distortion THD (resistive load)
Consumption Stand-by
Consumption « ON » no load
Overheat protection (+/-5°C)
Overload and short circuit protection
Reverse polarity protection
Deep discharge battery protection
Max. battery voltage
Acoustic alarm
General data
Weight
Dimensions
Protection index IP
Certification ECE-R 10 (E24)
EC conformity
Operating temperature
Relative humidity in operation
Ventilation forced
Acoustic level
Warranty
Approximate correction of Pnom
Recommended battery capacity
Length cables (Battery/left AC)

Options

Voltage max.
Current max.
Solar
Principle
regulator
Absorption voltage
Floating voltage
Plug for remote control (RCM)
∗ 120Vac/60Hz on request
∗∗ Standby with solar option -S
AJ 275-12
AJ 350-24
12V
24V
10.5 – 16V (24V max.)
21 – 32V (44V max.)
200VA
300VA
275VA
350VA
350VA
500VA
450VA
650VA
150VA
150VA
93%
94%
0.1 – 1 up to 200 VA
0.1 – 1 up to 300 VA
2W (only with the solar option -S)
2.3A (4.6A ) ∗
3.2A (6.4A ) ∗
0.3W∗∗
0.5W∗∗
2.4W
3.5W
2.4 kg
142mm x 163mm x 84mm
EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 60950-1
1.2m / 1m
AJ 275-12-S
AJ 350-24-S
25V
45V
10A
14.4V
28.8V
13.6V
27.2V
AJ V2.7
AJ 400-48
AJ 500-12
48V
12V
42 – 64V (64V max.)
10.5 – 16V (24V max.)
300VA
400VA
400VA
500VA
600VA
575VA
1000VA
1000VA
200VA
250VA
94%
93%
0.1 – 1 up to 300 VA
0.1 – 1 up to 400VA
4.6A (9.2A ) ∗
5.2A (10.4A ) ∗
Sine wave 230Vac (120Vac ) 0 / - 10%
50Hz (60Hz ) ± 0.05% (crystal controlled)
< 5% (@ Pnom.)
1.1W∗∗
0.4W
5.2W
4.6W
Shut down @ 75°C - Auto-restart @ 70°C
Automatic disconnection with 2 time restart attempt
Protected by internal fuse
Shut off @ 0.87 x Unom - Automatic restart @ Unom
Shut off @ >1.33 x Unom - Automatic restart @ < Umax
Before low battery or overheating disconnection
2.6 kg
IP 30 conforms to DIN 40050
Not available
-20°C up to +50°C
95% without condensation
From 45°C ± 5°C
< 45 dB (with ventilation)
5 years
-1.5%/°C since +25°C
> 5 x Pnom/Unom (recommended value in Ah)
AJ 400-48-S
AJ 500-12-S
90V
25V
Floating 3 stages (I/U/UO)
57.6V
14.4V
54.4V
13.6V
AJ 600-24
AJ 700-48
24V
48V
21 –32V (44V max.)
42 –64V (64V max.)
500VA
500VA
600VA
700VA
675VA
900VA
1200VA
1400VA
300VA
300VA
94%
94%
0.1 – 1 up to 500VA
0.1 – 1 up to 500VA
Adjustable : 1
20W
5.7A (11.4A ) ∗
7A (14A ) ∗
0.6W
1.5W
7.2W
12W
4.5 kg
142mm x 240mm x 84mm
Not available
1.5m / 1m
AJ 600-24-S
AJ 700-48-S
45V
90V
15A
28.8V
57.6V
27.2V
54.4V
13/50
AJ