BRUSHES CIRCUIT (GAS & DIESEL)
Conditions necessary for circuits to work
1. Battery Voltage
2. Key switch on
3. CB-7 closed
4. Brush switch in lower position
5. Solenoid (4) energized
6. Engine running
7. Neutral switch in either forward or reverse position
Brush lock up solenoid (9) holds brush deck up and off when engine is turned off. With neutral switch in
(Neutral), brushes will shut off after 2 seconds. Bush pressure switch closed, energizes solenoids (6 & 8).
1,1A,1D,9
BAT.
15 AMP.
CB-5
4
KEY SWITCH
9A
SCRUB
15 AMP.
BRUSHES
CB-7
SW.
28,28A
28A
4B,4C
(C)
28E
NEUTRAL SW.
OPEN IN FWD.
AND REV.
1-38
BRUSHES CIRCUITS
RAISE
29
BRUSH PRESSURE SW.
30A,52
2
1
LOWER (ON)
30A
3
28,28C
52
(C)
(NC)
(NC)
38B
TD2
12V BATTERY
SCRUB BRUSHES SOL. (6)
29
SCRUB BRUSHES SOL. (8)
31
7E,7G
SCRUB BRUSH LOCK UP SOL. (9)
53
ON-NORMAL ROTATION BRUSH SOL.( 4)
T112
31
7K,7L
American-Lincoln Technology
ATS 46/53 Troubleshooting Guide
7P,7N
7T,7S
7E,7G
7R,7Q
7W