4. FAN MOTOR removal
screw
screw
screw
screw
1) Remove the mounting screws(13 places).
Tape
3) Peel off the tapes.
2) Remove the PANEL TOP ASSY.
Reuse the tape.
screw
screw
4) Remove the mounting screws(4 places).
5) Pull the CASING.
MOTOR SHAFT
6) Loosen the MOTOR SHAFT screw.
7) Slide the left with the SIROCCO FAN and CASING.