Control/Status Interface - X8 - Siemens SIMOTICS S-1FL6 Operating Instructions Manual

Sinamics / simotics
Hide thumbs Also See for SIMOTICS S-1FL6:
Table of Contents

Advertisement

Connecting

4.3 Control/status interface - X8

● For FSC and FSD
400 V variant
● For FSAA and FSA
You can attach the motor power cable with the same method for 200 V variant drives of
frame sizes FSC and FSD.
● For FSB and FSC
The FSB and FSC servo drives are equipped with barrier terminals for motor power
connection. You can fix the motor power cable on the servo drives by using the M4
screws with a tightening torque of 2.25 Nm (19.91 lb.in).
4.3
Control/status interface - X8
Pin
Signal
Type: 20-pin MDR socket
Digital inputs/outputs
1
DI1
2
DI2
3
DI3
4
DI4
6
DI_COM
7
DI_COM
None
5
-
8
-
9
-
10
-
* The pins are used to connect the brake control signals for 200 V variant drive only.
80
Description
Digital input 1
Digital input 2
Digital input 3
Digital input 4
Common terminal for digital
inputs
Common terminal for digital
inputs
Reserved
Reserved
Reserved
Reserved
Pin
Signal
11
DO1+
Digital output 1, positive
12
DO1-
Digital output 1, negative
13
DO2+
Digital output 2, positive
14
DO2-
Digital output 2, negative
17
BK+
Motor holding brake control sig-
*
nal, positive
18
BK-
Motor holding brake control sig-
*
nal, negative
15
-
Reserved
16
-
Reserved
19
-
Reserved
20
-
Reserved
Operating Instructions, 09/2016, A5E37208830-002