Ambient Temperature; Ddc/Ci Support; Data For Edid & Inf File; Hot-Key Definition - Philips 192E1SB/70 Service Manual

18.5 lcd color monitor
Table of Contents

Advertisement

3.10 Data for EDID & INF file
Data for EDID & .inf file
1
User visible strings on .inf file
2
Manufacturer ID ( EDID data)
3
Product ID, "xxxx" 4 codes
4
maximum resolution
5
Horizontal Frequency Range
6
Vertical Frequency Range
7
Monitor Name (13 characterizes max.)

3.11 Hot-key definition

Item
Monitor Controls
Lock
Factory Mode
DDC/CI On/OFF
for VISTA
Any deviation between document and sample, please refer to Philips approved sample.
4

Visual characteristics

4.1 Test conditions

Unless otherwise specified, this specification is defined under the following conditions.
(1) Input signal:
(2) Luminance setting:
(3) Warm up:
(4) Ambient light:

(5) Ambient temperature:

4.2 Brightness

To follow Panel specification

4.3 Image size

Actual display size: Refer to 2.1 LCD PANEL spec.

4.4 Brightness uniformity

Set contrast at 100% and turn the brightness to get average above 300 nits at centre of the screen. Apply the Fig 1;
it should comply with the following formula:
Where B_max =Maximum brightness
B_min = Minimum brightness
Key
[Menu]
[AUTO]+[Menu]+[Power]
[MENU]+[DOWN]
As defined in 3.3, 1366*768
non-interlaced mode (1366*768@60Hz 146.25MHz), signal sources must
have 75 ohm output impedance
controls to be set to 300 nits with full screen 100 % duty cycle white signal
More than 30 minutes after power on with signal supplied.
400 -- 600 lux
20 ± 5 C
B_min
B_max
Philips 192E1(19inch WIDE LCD MONITOR 192E1)
PHL
MSB(byte 12): C0
LSB (byte 11): 2A
1366x768
30~83 KHz
56~76Hz
Philips 192E1
Key press time
OSD Timeout
6 sec
5 sec
5 sec
5 sec
X 100% > 75% (Follow panel spec)
Meridian 1
OSD Message
Monitor controls locked
Monitor controls
unlocked (default)
DDC/CI ON (default)
DDC/CI OFF