LED
R2
F
P1
R1
R2
Note
Primary user (radar) on all enabled channels
If the device detects a primary user (for example radar signals) on all enabled channels of
WLAN interface 1, the LEDs F and R1/R2 flash. No data traffic is then possible for the next
30 minutes. After this time, the device runs the scan again and checks whether a primary
user still exists. If no primary user is detected, data traffic is possible again.
The wait time of 30 minutes is necessary due to legal requirements and cannot be shortened
even by restarting the device.
SCALANCE W788-x / W748-1
Operating Instructions, 06/2016, A5E03678333-10
Color
Meaning
SCALANCE W7x8 in access point mode:
Flashing fast
yellow
With 802.11h, the channel is scanned for one minute for primary users
before the channel can be used for data traffic.
SCALANCE W7x8 in client mode:
The client waits for the MAC address due to the setting "Automatic" for
the "MAC mode" parameter and is connected to no access point.
SCALANCE W7x8 in client mode:
Yellow
flashing 3 x
The client waits for the MAC address due to the setting "Automatic" for
short, 1 x long
the "MAC mode" parameter and is connected to an access point.
SCALANCE W7x8 in access point mode:
Green
The WLAN interface is initialized and ready for operation.
SCALANCE W7x8 in client mode:
The LED is always off because the 2nd interface is not available in client
mode.
SCALANCE W7x8 in access point mode:
Green and yel-
low flashing
Data transfer over the second WLAN interface.
alternately
SCALANCE W7x8 in client mode:
The LED is always off because the 2nd interface is not available in client
mode.
SCALANCE W7x8 in access point mode:
Flashing fast
yellow
With 802.11h, the channel is scanned for one minute for primary users
before the channel can be used for data traffic.
SCALANCE W7x8 in client mode:
The LED is always off because the 2nd interface is not available in client
mode.
Red
An error occurred during operation with the SCALANCE W7x8.
Red
A primary user was found on all enabled channels.
R1 or R2 flash-
ing yellow simul-
taneously
Flashing yellow
"Flashing" enabled using SIMATIC NET Primary Setup Tool (PST).
Description
4.3 LED display