Server Interfaces; Np Uplinks - Cisco N9K-C93180YC-FX Configuration Manual

Configuring n port virtualization
Hide thumbs Also See for N9K-C93180YC-FX:
Table of Contents

Advertisement

Configuring N Port Virtualization

Server Interfaces

• In Cisco Nexus 9000 Series switches, server interfaces can be FC or vFC interfaces.
• Server interfaces are F ports on the edge switch that connect to the servers. A server interface may
• FC server interfaces should be in trunk mode off. Trunk mode on is not supported.
• vFC server interfaces should be in trunk mode on.
• Server interfaces are automatically distributed among the NP uplinks to the core switch. All of the end
• 8 G speed is not supported for server and target interfaces.
• The default speed is 16 G.

NP Uplinks

• In Cisco Nexus 9000 Series switches, NP uplink interfaces can be native Fibre Channel interfaces, virtual
• All interfaces from the edge switch to the core switch are configured as proxy N ports (NP ports).
• An NP uplink is a connection from an NP port on the edge switch to an F port on the core switch. When
• The features below must be enabled on the core switch:
• If the FC uplink speed is 8 G, the fill pattern should be configured as IDLE on the core switch.
support multiple end devices by enabling the N port identifier virtualization (NPIV) feature. NPIV
provides a means to assign multiple FC IDs to a single N port, which allows the server to assign unique
FC IDs to different applications.
To use NPIV, enable the NPIV feature and reinitialize the server interfaces that will
Note
support multiple devices.
devices connected to a server interface are mapped to the same NP uplink.
fiber channel interfaces, SAN port channel interfaces, or virtual ethernet port-channel interfaces.
an NP uplink is established, the edge switch sends a fabric login message (FLOGI) to the core switch
then (if the FLOGI is successful) registers itself with the name server on the core switch. Subsequent
FLOGIs from end devices connected to this NP uplink are forwarded as-is to the core switch. Subsequent
flags from the same VSAN are forwarded as fdisc.
In the switch CLI configuration commands and output displays, NP uplinks are called
Note
External Interfaces.