Pin Assignment - Siemens SIMATIC ET 200AL Manual

Communication module cm 4xio-link 4xm12
Hide thumbs Also See for SIMATIC ET 200AL:
Table of Contents

Advertisement

Wiring

3.2 Pin assignment

3.2
Pin assignment
Note
Color coding
The sockets for ET-Connection and the power supply of the modules are color-coded. These
colors correspond to the colors of the offered cables.
Pin assignment of the IO-Link sockets
Note
Port Class B
The pin assignment of the IO-Link interface corresponds to the IO-Link specification as per
Port Class B. Port Class B is specially suited for the connection of actuators with additional
supply (e.g. valve terminals).
To connect devices with Port Class A (e.g. sensors) to the communication module
CM 4xIO-Link 4xM12, a 3-wire connection cable should be used (Port Class A compatibility).
The table below shows the pin assignments of the 4 sockets for the connection of IO-Link.
Table 3- 1
Pin
1
2
3
4
5
* If you use the sockets for IO-Link as Port Class A, you may
not place any signals on pins 2 and 5.
The M12 connectors are designed according to IO-Link specification as port type Class B.
Pins 2 and 5 contain an additional power supply.
Reaction-free connection of devices with different port types (Class A and Class B) is
possible using a 3-wire connecting cable (assignment of pins 1, 3 and 4).
16
Pin assignment of the IO-Link
Assignment
X10 to X13 - sockets for IO-Link
24 V encoder supply 1U
S
24 V actuator supply 2U
A
Encoder supply ground 1M
Port 1 (C/Q): Connector X10
Port 2 (C/Q): Connector X11
Port 3 (C/Q): Connector X12
Port 4 (C/Q): Connector X13
Ground for actuator supply 2M
(from 1L+)
(from 2L+)
Communication module CM 4xIO-Link 4xM12(6ES7147-5JD00-0BA0)
Front view of the sockets
Port Class A (Type A)*
Port Class B (Type B)
Manual, 10/2017, A5E32352322-AE