Preparing Water Piping; To Check The Water Volume And Flow Rate; Preparing Electrical Wiring; Overview Of Electrical Connections For External And Internal Actuators - Daikin CHYHBH05AA Installation Manual

Daikin hybrid for multi heat pump – heat pump module
Hide thumbs Also See for CHYHBH05AA:
Table of Contents

Advertisement

4 Installation

A (m
)
2
100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.5
A
Minimum floor area for hybrid unit (m
B
Total refrigerant charge in the system (kg)
H
The height measured from the floor to the bottom of the
casing. The graph is based on the height measured from
the floor to the flare nut.
▪ The indoor unit is designed for indoor installation only (in a
technical room or similar) and for ambient temperatures ranging
5~30°C in heating mode.
3.2

Preparing water piping

NOTICE
In case of plastic pipes, make sure they are fully oxygen
diffusion tight according to DIN  4726. The diffusion of
oxygen into the piping can lead to excessive corrosion.
3.2.1

To check the water volume and flow rate

Minimum water volume
Check that the total water volume in the installation is minimum
13.5 litre, the internal water volume of the indoor unit NOT included.
INFORMATION
In critical processes, or in rooms with a high heat load,
extra water might be required.
NOTICE
When circulation in each space heating/cooling loop is
controlled by remotely controlled valves, it is important that
the minimum water volume is guaranteed, even if all of the
valves are closed.
Minimum flow rate
Check that the minimum flow rate (required during defrost/backup
heater operation) in the installation is guaranteed in all conditions.
NOTICE
When circulation in each or certain space heating loops is
controlled by remotely controlled valves, it is important that
the minimum flow rate is guaranteed, even if all valves are
closed. In case the minimum flow rate cannot be reached,
a flow error 7H will be generated (no heating or operation).
See the installer reference guide for more information.
Minimum required flow rate
05+08 models
See the recommended procedure as described in
during commissioning" on
page 20.
Installation manual
6
B (kg)
2
)
9 l/min
"6.2  Checklist
3.3

Preparing electrical wiring

3.3.1
Overview of electrical connections for
external and internal actuators
Item
Description
Outdoor unit and indoor unit power supply
1
Power supply for
outdoor unit
2
Power supply and
interconnection cable to
indoor unit
3
Power supply gas
boiler
User interface
4
User interface
Optional equipment
5
3‑way valve
6
Domestic hot water
tank thermistor
7
Room thermostat/heat
pump convector
8
Outdoor ambient
temperature sensor
9
Indoor ambient
temperature sensor
Field supplied components
10
Shut-off valve
11
Domestic hot water
pump
12
Alarm output
13
Changeover to external
heat source control
14
Space heat operation
control
15
Safety thermostat
(a)
Refer to name plate on outdoor unit.
(b)
Minimum cable section 0.75 mm².
(c)
Use the cable supplied with the boiler.
(d)
The thermistor and connection wire (12 m) are delivered
with the domestic hot water tank.
(e)
Cable section 0.75 mm² till 1.25 mm²; maximum length:
50 m. Voltage-free contact shall ensure the minimum
applicable load of 15 V DC, 10 mA.
(f)
Cable section 0.75 mm² till 1.25 mm²; maximum length:
500 m. Applicable for both single user interface and dual
user interface connection.
(g)
Cable section 1.5 mm
NOTICE
More technical specifications of the different connections
are indicated on the inside of the indoor unit.
4
Installation
4.1

Opening the units

4.1.1
To open the switch box cover of the
indoor unit
1 Remove the side panel at the right side of the indoor unit. The
side panel is fixed at the bottom with 1 screw.
Daikin hybrid for multi heat pump – heat pump module
Wires
Maximum
running
current
(a)
2+GND
(g)
3+GND
(c)
2+GND
(f)
2
(b)
3
100 mA
(d)
2
(b)
3 or 4
100 mA
(b)
2
(b)
2
(b)
2
100 mA
(b)
2
(b)
2
(b)
2
(b)
2
(e)
2
2
; maximum length: 50 m.
CHYHBH05+08AA
4P471756-1C – 2017.10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chyhbh08aa

Table of Contents