Chapter 2
Preparing for Installation
This equipment must be externally grounded using a customer-supplied ground wire before
Warning
power is applied. Contact the appropriate electrical inspection authority or an electrician if you
are uncertain that suitable grounding is available. Statement 366
Warning
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Statement 1001
Connect the unit only to DC power source that complies with the safety extra-low voltage (SELV)
Warning
requirements in IEC 60950 based safety standards. Statement 1033
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. Statement
Warning
1023
Caution
Power injectors must be used indoors only. Do not place a power injector in an unprotected outdoor
environment because water could get into the power injector and cause a short circuit and possible fire.
Caution
When the access point is installed outdoors or in a wet or damp location, the AC branch circuit that is
powering the access point should be provided with ground fault protection (GFCI), as required by Article
210 of the National Electrical Code (NEC).

Translated Safety Warnings

The document containing the Translated Safety Warnings for Cisco Aironet 1570 Series Outdoor Access
Points is provided on the following page on Cisco.com:
http://www.cisco.com/c/en/us/products/collateral/wireless/bulletin-c25-735595.html
OL-32138-01
Cisco Aironet 1570 Series Outdoor Access Point Hardware Installation Guide
Translated Safety Warnings
2-9