Operation; Manual Regeneration; Maintenance; Troubleshooting - Pentair AUTOTROL 255 Logix 740 User Manual

Hide thumbs Also See for AUTOTROL 255 Logix 740:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
Regeneration time
A
G
Press
.
Regeneration time flashes.
H
Adjust displayed time with
Default setting: 2:00am.
A
I
Press
to validate the selection and advance to the next parameter.
The following steps appears after regeneration time, do not modify them :
A
Days to regenerate (740 Time-clock controller only)
Calendar override (760 Demand controller only)
Estimated capacity
4.2.
History
To access the recorded information, press simultaneously
5 .

Operation

5.1.
Recommendations
• Use only regenerate salts designed for water softening EN973;
• For optimal system operation, the use of clean salt free from impurities is recommended (for example salt pellets);
• Do not use ice melt, block, or rock salts;
• The sanitizing process (both with liquid and electrochlorination) introduces chlorine elements which may reduce the life of
the ion exchange resins. Refer to the technical guides for resins in common use, providing necessary checks on the system.
5.2.

Manual regeneration

A
Note:
The unit returns to normal operation if no buttons are pressed within 30 seconds.
Immediate regeneration
A
Press and hold
for 5 seconds.
Regeneration icon displayed.
Camshaft starts rotating to cycle C1.
Manual delayed regeneration
The regeneration will start on the scheduled date
A
Press
.
Regeneration icon flashes.
6 .

Maintenance

A
Mandatory:
Cleaning and maintenance shall take place at regular intervals in order to guarantee the proper
functioning of the complete system, and be documented in the Maintenance record book.
7 .

Troubleshooting

Please follow this procedure for any technical support:
A
Collect the required information for a technical assistance request.
Product identification (see 2.1. Safety tags location, page 5 and Original settings, page 2;
Error number displayed on the controller;
B
Contact your local dealer who installed this device (see contact details on last page).
Also call him if the water tastes salty, if the water is not softened or if there is no salt consumption.
Ref. MKT-UG-001 / A - 14.10.2016
A
A
and
.
Amount of regenerant used per regeneration
Hardness (760 Demand controller only)
A
A
and
when the controller is in service mode.
Immediate double regeneration
B
When cycle C1 starts, press and hold
x2 icon displayed.
A
Note:
The second regeneration begins after current
regeneration completed.
Note:
A
To cancel: press
User Guide 255 / LOGIX 740-760
A
1
2
3
4
5
R
for 5 seconds.
again.
7
6
7
7 / 28

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Autotrol logix 255 seriesAutotrol logix 740Autotrol logix 760

Table of Contents