Pentair CARBON FILTRATION SYSTEM 1.0 Installation And Service Manual

Pentair CARBON FILTRATION SYSTEM 1.0 Installation And Service Manual

Whole house carbon filtration systems
Hide thumbs Also See for CARBON FILTRATION SYSTEM 1.0:

Advertisement

Quick Links

WHOLE HOUSE CARBON FILTRATION SYSTEMS
INSTALLATION AND SERVICE MANUAL
pentair.com/homewater

Advertisement

Table of Contents
loading

Summary of Contents for Pentair CARBON FILTRATION SYSTEM 1.0

  • Page 1 WHOLE HOUSE CARBON FILTRATION SYSTEMS INSTALLATION AND SERVICE MANUAL pentair.com/homewater...
  • Page 2: Table Of Contents

    “jumper wire” to bridge the equipment and re-establish the contiguous conductive nature of the plumbing before using this Pentair system. Failure to do so can result in errant electricity from improperly grounded appliances or potential galvanic activity in the plumbing system, which could increase the risk of fire or injury while using your home appliances. Please consult a licensed electrician before attempting to install.
  • Page 3: System Information

    SERVICE FLOW PSI DROP AT MODEL MEDIA AMOUNT CHLORINE CAPACITY DRAIN FLOW RATE RATE SERVICE FLOW (CU.FT) (GAL) (GAL/MIN) (GAL/MIN) RATE PENTAIR CARBON 1.0 CARBON 11.6 400,000 FILTRATION SYSTEM 1.0 PENTAIR CARBON 1.5 CARBON 11.9 600,000 FILTRATION SYSTEM 1.5 PENTAIR CARBON FILTRATION 2.0 CARBON...
  • Page 4: Annual Maintenance Requirements

    PRE-INSTALLATION INSTRUCTIONS • Do not install this system where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. • This system must be installed in an area that is not affected by extreme heat, cold or the elements. The selected installation area must be adequate for easy service of all parts.
  • Page 5: Installation Instructions

    INSTALLATION INSTRUCTIONS 1. SAFETY PRECAUTIONS • To prevent accident or injury, do not hoist the unit over your shoulder. Use a hand truck to transport the unit. Notice Do not lay the unit on its side during transportation and/or installation. •...
  • Page 6 • In some homes, metal piping may serve as a ground connection for the home electrical system. Installing a Pentair Filter with its nonmetallic valve body will interrupt the ground connection. Whenever a system is installed on metallic plumbing, we recommend you use grounding pipe clamps and a ground cable to maintain continuity of the ground connection from the inlet to the outlet pipe.
  • Page 7 Special Attention for situations where a Filter and a Softener are installed together: When a whole house filter and a softener are installed side by side, the preferred approach is to run a separate drain line from each unit all the way to the point of termination. If this is not done, there is the potential for drain water from the filter to back feed through the softener and overfill the brine tank, especially when drain lines are run overhead.
  • Page 8 QUICK START GUIDE: SYSTEM START-UP INSTRUCTIONS CONTINUED 1. Connect the unit to the existing plumbing: (Facing the front of the system, INLET is on the LEFT – OUTLET is on the RIGHT) WARNING The bypass is only hand tightened at the factory and must be fully tightened and checked for leaks by the installer.
  • Page 9: Start Up Instructions

    QUICK START GUIDE: SYSTEM START-UP INSTRUCTIONS Notice To avoid damage, do not backwash filter for a minimum of 24 hours! 8. Confirm the system is plumbed correctly: inlet on left, outlet on right. If there is a softener installed after the carbon filter, place the softener system in bypass. Follow the softener start up instructions after the filter is complete.
  • Page 10: Control Information

    CONTROL INFORMATION POWER ON LED A green LED is ON when power is applied to the control and the microprocessor is operating properly. SERVICE REQUIRED If the message “For Service Call” or “Service Required” displays in the window of the control without showing the time of day, the control valve has encountered a problem, such as failure to reach the proper position during regeneration.
  • Page 11: Programming The Control

    HOW TO PROGRAM THE INSTALLER’S LEVEL KEY BUTTONS: SCROLL BUTTON UP ARROW POWER POWER DOWN ARROW To begin, verify that the control is in the Service Mode. Time of Day GL Remaining • Press the DOWN ARROW and hold it for 5 seconds; the control will display: System Check •...
  • Page 12 • If you do not want to change the phone number, leave this setting at NO. Press SCROLL to advance to the next setting. • To change the number, select YES; Press the UP or DOWN ARROW and then enter the service phone number.
  • Page 13 ADVANCED MENU Notice On WF10-P, WF8-P, WF6-P and WF4-P Iron & Sulfur Systems, you must use the advanced menu to set the calendar override to 3 days. See step 4 for more details. 1. RESET AVERAGE The control will display: Reset Average No •...
  • Page 14 4. DAYS OVERRIDE The control will display: Override: OFF • Press the UP or DOWN ARROW to set the number of days between regenerations. The setting range is OFF to 30 days. Notice In most situations with carbon filter, override can remain “OFF”. Set a number of days if you wish to have the filter be refreshed periodically regardless of water use.
  • Page 15 7. CYCLE 3 - FAST RINSE/BRINE REFILL The control will display: FILL/RNS: 3 min • Press the UP or DOWN ARROW to change the length of the fast rinse. The setting range is 0 to 99 minutes (maximum limit). Notice In most applications, this setting will not need adjusting.
  • Page 16 HOW TO PROGRAM THE END USER’S LEVEL To begin, verify that the control is in the Service Mode. Time of Day GL Remaining Press the SCROLL BUTTON to advance to the next setting. The following settings are available in the End User’s Level: 1.
  • Page 17: Understanding The Diagnostic Level

    UNDERSTANDING THE DIAGNOSTIC LEVEL To begin, verify that the control is in the Service Mode. Time of Day GL Remaining • Press the UP ARROW and hold it for 5 seconds; the control will display: Regen _ Days Ago The control is now in the Diagnostic Level. Use the SCROLL BUTTON to advance to each diagnostic. If no button is pressed within 5 minutes, the display will return to the Service Mode.
  • Page 18: Exploded Views And Parts Lists

    VALVE EXPLODED VIEW 18 • WHOLE HOUSE CARBON FILTRATION SYSTEM...
  • Page 19 VALVE PARTS LIST ITEM PART NUMBER DESCRIPTION 70793 3/4 NPTF TO 1/2 ID HOSE MALE ELBOW (OPTIONAL) BACKWASH FLOW CONTROL 5.0 GPM ( SIZE 1.0 & 1.5 CARBON) 75074 75075 BACKWASH FLOW CONTROL 6.0 GPM (SIZE 1.0 ACID NEUTRALIZER) 75076 BACKWASH FLOW CONTROL 7.0 GPM (SIZE 2.0 CARBON) 72678 SCREW 1/4-20 X 1-1/4 LG HEX WASHER HD...
  • Page 20 20 • WHOLE HOUSE CARBON FILTRATION SYSTEM...
  • Page 21 CONTROL PARTS LIST ITEM QUANTITY PART NUMBER DESCRIPTION 39497 FRONT COVER ASSY, PENTAIR ROTARY 38752 BOARD ASSY FILTER WITH 2 LINE DISPLAY 70618 SCREW #4-24 X 3/8 LG SELF-THREADING 72519 FLOW METER SENSOR CABLE NGC 72134 HEYCO BUSHING, SR 5P-4...
  • Page 22 BYPASS VALVE EXPLODED VIEW AND PARTS LIST BYPASS VALVE ASSEMBLY PART NUMBER 72668 ITEM QUANTITY PART NUMBER DESCRIPTION 72599 SCREW 6X32X1/2 TYPE 72580 BYPASS END CAP 541 13328 017 O-RING 8730 72584 RETAINING RING VS-15 71161 568-363 NUT, BYPASS VALVE 71162 568-364 RING, NUT RETAINER 71110...
  • Page 23 10 X 54 TANK BLACK W/BASE 1.5 38258 12 X 48 TANK BLACK W/BASE 2.0 83489 PENTAIR ROTARY VALVE CARBON FLT 1.0 & 1.5 WITH BYPASS 83490 PENTAIR ROTARY VALVE CARBON FLT 2.0 WITH BYPASS 18961 RISER PIPE ASSY 1.0 18962 RISER PIPE ASSY 1.5...
  • Page 24 Tank Size DIM A DIM B DIM C 10-1/4 in 10x44 46 in 51 in 10-1/4 in 55-7/8 in 61-1/4 in 10x54 55-1/4 in 12x48 12 in 50 in 3 in 8 3/4 in 14 1/2 in 4 3/4 in Ø...
  • Page 25: Troubleshooting Guide

    TROUBLESHOOTING GUIDE SYMPTOM CAUSE SOLUTION 1. Untreated water 1. Open bypass valve. 1. Close the bypass valve. to service. 2. Loss of filter media. 2. Refer to SYMPTOM #4. 3. The valve is in regeneration. 3. Wait for the regeneration to complete. 4.
  • Page 26 TROUBLESHOOTING GUIDE SYMPTOM CAUSE SOLUTION 3. The valve cycles Defective or shorted microswitches. Replace the microswitches. continuously. 1. Excessive backwash/fast rinse flow. 1. Verify that the backwash flow control 4. Loss of filter is installed and sized correctly. media through the drain line.
  • Page 27: Warranty Information

    PRODUCT WARRANTY AND REGISTRATION FORM For details on your Pentair product warranty, please visit pentair.com/assets/residential-filtration-warranty. Warranty Registration Form Send in this Warranty Registration Form to validate your warranty or visit pentair.com/register-warranty to complete the warranty registration form online. Date Item(s) were Received:...
  • Page 28 28 • WHOLE HOUSE CARBON FILTRATION SYSTEM...
  • Page 29 WHOLE HOUSE CARBON FILTRATION SYSTEM • 29...
  • Page 30 2361 Mason Ave | Suite 100 | Daytona Beach, FL 32117 | United States P: 877.842.1635 | Technical Services: 877.842.1635 | pentair.com/homewater © 2022 Pentair. All indicated Pentair trademarks and logos are property of Pentair. Third party registered 37298 REV D JA22...

Table of Contents