York SUNLINE 2000 B1HN090 Manual

Single package air-to-air dual fuel heat pumps, 7-1/2 & 10 nominal tons

Advertisement

DESCRIPTION

YORK Sunline 2000 Dual Fuel Heat Pumps are convertible
single package units designed for light commercial
applications. They can easily be installed on a roof curb, slab,
roof jack or frame.
These units not only include all the features and benefits of a
typical heat pump system, their gas-fired furnaces provide all
the added features and benefits of a fossil fuel system.
Units are self-contained and assembled on rigid full perimeter
base rails allowing for 3-way fork lift access and overhead
rigging. Every unit is completely charged, wired, piped and
tested at the factory to provide for a quick and easy field
installation.
Both down and side discharge airflows are available without
having to swap panels. The installer simply removes the duct
covers for the desired configuration. Economizers may be used
on either side or down discharge applications with no
modifications required.
All models include a 5-year limited warranty on compressors,
a 10 year limited warranty on gas-fired heat exchangers, and
a 1-year limited warranty on all other parts.

FEATURES

CONTROLS - Th es e h ea t p um p s u ti li z e a u ni que
time-temperature defrost circuit which adjusts the time
between defrost cycles based on the outdoor temperature to
provide optimal comfort control and ensure reliable operation.
The ambient modified, time-temperature defrost control
extends the time below 35°F and shortens the time above 35°F.
The nominal defrost times are field adjustable to 50, 80, and
110 minutes. The defrost time is initiated and terminated by a
liquid line control with a 10 minute override limit built into the
defrost control.
These heat pumps are designed to optimize comfort and
minimize energy usage. An adjustable balance point control is
standard with every unit to select the optimum changeover
temperature.
HIGH EFFICIENCY - Their high efficiencies exceed all
legislated minimum levels and provide low operating costs.
SINGLE PACKAGE
AIR-TO-AIR
DUAL FUEL HEAT PUMPS
B1HN090 & 120
7-1/2 & 10 NOMINAL TONS
(9 EER)
SUNLINE 2000™
CONVERTIBLE AIRFLOW DESIGN - Both the side and
bottom duct openings are covered when they leave the factory.
If a side supply / side return is desired, you simply remove the
two side duct covers from the outside of the unit and discard
them. If a bottom supply / return is desired, you simply remove
the two bottom duct covers and discard them. No panel cutting
or swapping is required! Convertible airflow design allows
maximum field flexibility and minimum inventory.
FACTORY-INSTALLED OPTIONS - S i ng le E n thalpy
Economizers can be installed at the factory. They are shipped
installed and wired. The outdoor air hood needs only to be field
assembled and installed.
Adjustable belt-drive blowers are available on most models
from the factory for complete air flow flexibility.
FIELD INSTALLED ACCESSORIES - Accessories were
designed for quick and easy installation. The motorized damper
and economizers simply slide in and electrical connections are
made by modular plugs. Propane and high altitude kits are also
available to cover all gas heating applications.
MOTORIZED AIR DAMPER - Includes slide-in / plug-in damper
assembly with rainhood and filters. The outdoor air dampers open
when the indoor fan motor is energized. Damper capable of
providing 0% thru 100% of outdoor return air opening.
MANUAL OUTDOOR DAMPER - Provides 0% thru 35% or 0%
thru 100% of outdoor return air opening (field adjustable).
Designed for duct mounted side or bottom supply / return
applications. Includes both hood assembly and filters.
ROOF CURB - The 14" high roof curb is shipped knocked
down. The roof curb has an insulated deck.
WIDE RANGE OF INDOOR AIRFLOWS - All models operate
from 300 to 500 cfm / ton. Indoor fan motors are belt-drive type
providing maximum flexibility to handle all airflow requirements.
A high horsepower motor is standard with every unit.
FULL PERIMETER BASE RAILS - The permanently attached
base rails provide a solid foundation for the entire unit and
protect the unit during shipment. The rails provide fork lift
access from 3 sides and rigging holes are also provided so that
an overhead crane can be used to place the units on a roof.
UTILITY CONNECTIONS MADE EASY - Gas and electric
utility knockouts are provided in the unit underside as well as
the side of the unit. A clearly identified location is provided to
mount a field supplied electrical disconnect switch. Utility
connections can be made quickly and with a minimum amount
of field labor.
511.17-TG2Y (598)
Cont'd.

Advertisement

Table of Contents
loading

Summary of Contents for York SUNLINE 2000 B1HN090

  • Page 1: Description

    DESCRIPTION CONVERTIBLE AIRFLOW DESIGN - Both the side and YORK Sunline 2000 Dual Fuel Heat Pumps are convertible bottom duct openings are covered when they leave the factory. If a side supply / side return is desired, you simply remove the...
  • Page 2: Table Of Contents

    511.17-TG2Y FEATURES - CONT’D. SIMPLE CONTROL CIRCUIT - A low voltage printed circuit AIR FILTERS - Units come standard with 2" throwaway filters. The unit filter racks can accommodate 1" or 2" filters without board contains a low voltage terminal strip. An additional set of any modifications.
  • Page 3: Ratings

    511.17-TG2Y RATINGS COOLING HEAT PUMP GAS HEAT CAPACITY (SEE NOTE 3) SOUND CAPACITY HTG. CAPACITY RATING TEMP. @ 47° MODEL (SEE NOTE 1) INPUT OUTPUT AFUE S.S.E. S.E. RISE LINE SIZE (SEE NOTE 2) 80/67-95°F (SEE NOTE 1) (MBH) (MBH) (bels) (°F) (in.
  • Page 4: Physical Data

    511.17-TG2Y PHYSICAL DATA MODEL CENTRIFUGAL BLOWER (Dia. x Wd. in.) 12 x 12 15 x 12 SUPPLY AIR BLOWER FAN MOTOR HP ROWS DEEP INDOOR FINS PER INCH COIL FACE AREA (Sq. Ft.) 13.4 PROPELLER DIA. (in.) 24 ea. 24 ea. OUTDOOR FANS FAN MOTOR HP...
  • Page 5: Cooling Capacities

    511.17-TG2Y COOLING CAPACITIES - 7-1/2 TON (BHN090) Temperature of Air on Outdoor Coil Air On Indoor 85°F 95°F Coil Sensible Capacity , MBH Sensible Capacity , MBH Total Power Total Power Entering Dry Bulb, °F Entering Dry Bulb, °F Cap. Input Cap.
  • Page 6 511.17-TG2Y COOLING CAPACITIES - 10 TON (BHN120) Temperature of Air on Outdoor Coil Air On Indoor 85°F 95°F Coil Sensible Capacity , MBH Sensible Capacity , MBH Total Power Total Power Entering Dry Bulb, °F Entering Dry Bulb, °F Cap. Input Cap.
  • Page 7: Heating Capacities

    511.17-TG2Y HEAT PUMP HEATING CAPACITIES* BHN090 OUTDOOR AIR TEMPERATURE, °F (72% RH) RET. AIR °F & KW - 10 2250 3000 3750 BHN120 OUTDOOR AIR TEMPERATURE, °F (72% RH) RET. AIR °F & KW - 10 3000 10.1 10.5 10.1 4000 10.5 10.1...
  • Page 8: Blower Performance

    511.17-TG2Y BLOWER PERFORMANCE - (7-1/2 & 10 TON SUPPLY AIR) MODEL BHN090 - (SIDE DUCT APPLICATIONS) BLOWER SPEED, 2250 2550 3000 3400 3750 0.83 1.16 1.08 0.66 1.27 1.18 0.37 1.45 1.35 0.08 1.65 1.54 1025 0.98 1.21 1.13 0.82 1.34 1.25 0.52...
  • Page 9: Electrical Data

    511.17-TG2Y ELECTRICAL DATA SUPPLY TOTAL MAXIMUM OUTDOOR COMPRESSOR UNIT FUSE BLOWER (#1 and #2)* AMPACITY, SIZE, POWER MOTOR, MOTOR, MODEL AMPS AMPS SUPPLY (#1 & #2) EACH EACH EACH 208/230-3-60 14.1 43.8 BHN090 460-3-60 22.0 575-3-60 18.4 208/230-3-60 17.3/16.7 10.6 55.9 BHN120 460-3-60...
  • Page 10: Unit Dimensions

    511.17-TG2Y UNIT DIMENSIONS - (BHN - 7-1/2 & 10 TON) RETURN AIR SUPPLY AIR OUTDOOR AIR OUTDOOR AIR (Economizer) CLEARANCES Front 24" All dimensions are in inches. They are 12" (Less Economizer) subject to change without notice. Certified Back 36" (With Economizer/ dimensions will be provided upon request.
  • Page 11 511.17-TG2Y UNIT DIMENSIONS - (BHN - 7-1/2 & 10 TON) (Cont’d.) DUCT COVERS - Units are shipped with all air duct openings covered. For side duct applications; 1.Remove and discard the supply and return air duct covers. 2.Connect ductwork to duct flanges on the rear of the unit.
  • Page 12: Corner Weights

    511.17-TG2Y 4 POINT LOADS 6 POINT LOADS 4 - POINT LOADS (LBS) UNIT TOTAL 1,237 1,612 6 - POINT LOADS (LBS) UNIT TOTAL 1,237 1,612 NOTE: These weights are with economizer and 24kW electric heat. Unitary Products Group...
  • Page 13: Roof Curb Dimensions

    511.17-TG2Y ROOF CURB DIMENSIONS - (BHN - 7-1/2 & 10 TON) 17-9/16" *Supply and Return Air (including duct support rails) as shown, are typical for bottom duct applications. For location on horizontal duct applications (on back of unit), refer to Unit Dimension details. ROOF CURB BENEFITS The 4"...
  • Page 14: Field-Installed Accessories

    511.17-TG2Y FIELD-INSTALLED ACCESSORIES SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZER - ROOF CURB - This 14" high full perimeter roof curb is shipped Includes a slide-in / plug-in damper assembly with fully knocked down for field assembly and contains duct supports modulating spring return motor actuator capable of introducing and an insulated deck in the area under the unit’s outdoor up to 100% outdoor air, one outdoor air electronic enthalpy section.
  • Page 15 511.17-TG2Y Unitary Products Group...
  • Page 16 Unitary Products Group P.O. Box 1592, York, Pennsylvania USA 17405-1592 511.17-TG2Y Subject to change without notice. Printed in U.S.A. Copyright © by York International Corporation 1998. All Rights Reserved. Code: EBY, EGY Supersedes: 511.17-TG2Y(294)

This manual is also suitable for:

Sunline 2000 b1hn120

Table of Contents