1.3.2

Reading range on flat metallic carrier plates

The transponder generally has linear polarization. The polarization axis runs as shown in the
diagram below. If the tag is centrically mounted on a flat metal plate, which may either be
almost square or circular, it can be aligned in any direction since the transmitting and
receiving RF660A antennas operate with circular polarization.
Figure 1-2
Table 1- 1
Carrier plate material
Metal plate of at least Ø 150 mm
Metal plate Ø 120 mm
Metal plate Ø 85 mm
Metal plate Ø 65 mm
On rectangular carrier plates, the reading distance depends on the mounting orientation of
the transponder
SIMATIC RF640T Gen 2
Operating Instructions, 05/2009, J31069-D0197-U001-A2-7618
Optimum positioning of the transponder on a (square or circular) metal plate
Reading range on flat metallic carrier plates
SIMATIC RF640T Gen 2
Reading range
100%
Approx. 80%
Approx. 55%
Approx. 40%