INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS

INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
Flat head
wood screw
7
Battery
cover
"
!
Flat head
wood screw
Batteries
5
3
Filter
7
Flat head
wood screw
2
Wireless remote control
The provided Remote Controller is a wireless
type, which also can be used as a wire.
Please see "How to Connect The Remote
Controller for Wired Operation", in case of
wired control is required.

Optional Installation Parts

Part
Parts name
code
Refrigerant piping
Liquid side : Ø6.35 mm
Gas side
: Ø9.52 mm
A
(RAS-10, 13PKVSG-E)
: Ø12.70 mm
(RAS-16PKVSG-E)
Pipe insulating material
B
(polyethylene foam, 6 mm thick)
Putty, PVC tapes
C
01_1118350131-EN.indd 6
01_1118350131-EN.indd 6
Refrigerant piping
must be protected from
physical damage.
Install a plastic cover or
equivalent.
Vinyl tape
Apply after carrying
out a drainage test.
4
Remote control
holder
• Secure the outdoor unit with fi xing bolts and nuts if the unit is likely to be
Q'ty
• Use Ø8 mm or Ø10 mm anchor bolts and nuts.
• If it is necessary to drain the defrost water, attach drain nipple # and cap
One
each
1
One
each
6
Hook
1
Installation
plate
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Shield pipe
Do not allow the drain hose to get slack.
Make sure to run the drain hose sloped
downward.
The fl are connection should be installed
outdoors.
Saddle
Insulate the refrigerant pipes separately
with insulation, not together.
Extension drain hose
(Not available, provided
by installer)
Fixing bolt arrangement of outdoor unit
exposed to a strong wind.
water proof $ to the bottom plate of the outdoor unit before installing it.
108 mm
28 mm
Air outlet
600 mm
For the rear left and left piping
Wall
Right
Rear
right
Left
Bottom
Rear
right
left
Bottom left
Cut the piping
hole sloped
slightly.
6 mm thick heat resisting
polyethylene foam
125 mm
Air inlet
90 mm
Drain outlet