INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS

INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
8
(
Flat head
Battery cover
wood screw
&
Flat head
wood screw
3
Batteries
The provided Remote Controller is a wireless type,
which also can be used as a wire.
Please see "How to Connect The Remote Controller
for Wired Operation", in case of wired control is
required.
Remark :
• Detail of accessory and installation parts can see in the accessory
sheet.
• Some pictures might be different from the actual parts.

Optional Installation Parts

Part
Parts name
code
Refrigerant piping
Liquid side
: Ø6.35 mm
Gas side
: Ø9.52 mm
A
(RAS-10, 13N3KV2 Series)
: Ø12.70 mm
(RAS-16N3KV2 Series)
Pipe insulating material
B
(polyethylene foam, 6 mm thick)
C
Putty, PVC tapes
1110251276-EN.indd 2
1110251276-EN.indd 2
5
Filter
8
4
Flat head
wood screw
Vinyl tape
Apply after carrying
out a drainage test.
2
Wireless remote control
Q'ty
One
each
1
One
each
Hook
1
Installation
plate
Shield pipe
Remote control holder
Saddle
Extension
drain hose
(Not available,
provided by installer)
Fixing bolt arrangement of outdoor unit
• Secure the outdoor unit with fi xing bolts and nuts if the unit is likely to be
exposed to a strong wind.
• Use Ø8 mm or Ø10 mm anchor bolts and nuts.
• If it is necessary to drain the defrost water, attach drain nipple 9 and cap
water proof ! to the bottom plate of the outdoor unit before installing it.
108 mm
28 mm
Air outlet
2
For the rear left and left piping
Wall
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose sloped
downward.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Left
Bottom
Rear
right
left
Bottom left
Insulate the refrigerant pipes separately
with insulation, not together.
6 mm thick heat resisting
polyethylene foam
125 mm
Air inlet
90 mm
600 mm
Drain outlet