Cisco CISCO7206 Regulatory Compliance And Safety Information Manual page 8

7200 series routers
Hide thumbs Also See for CISCO7206:
Table of Contents

Advertisement

Port Adapters
Installation Requirements
This section describes special installation requirements for the 4T port adapter.
Where applicable, the 4T port adapter is approved only for installation in a host and with host
attachments, which are either type approved for such apparatus or covered by a General Approval.
Except at the edge connector, which plugs into the router's midplane, clearance and creepage
distances of X millimeters (mm) and Y mm, as listed in Table 1, must be maintained between the 4T
port adapter and other parts of the host, including any other port adapters.
Creepage distance is defined as the minimum distance between two points (following the contour of
the insulator) measured across the surface of an insulator. Clearance distance is defined as the
minimum distance between two points (line of sight) measured in air.
Table 1
Voltage Used or Generated by Other Parts
of the Host or Expansion Card (Vrms
Up to 50
Up to 125
Up to 250
Up to 300
1. Vrms = root mean square voltage.
2. VDC = volts direct current.
3. The creepage distances not in parentheses apply when the equipment is installed in a normal office environment. The larger
dimensions, given in parentheses, must be applied when the equipment is installed in an environment in which dust and other
types of pollution could conduct electricity because of the effects of dampness and condensation. This applies to locations
subject to high humidity.
4. For working voltages exceeding 300V, consult a competent telecommunications engineer prior to installation.
Clearance and creepage distances are measured between adjacent parts, as shown in Figure 5.
Figure 5
8
Creepage and Clearance Distances Based on Voltage
4
Creepage and Clearance Distance Measurements
Communication module
Power supply unit
or other source of
excessive voltage
Y
1
2
or VDC
)
Creepage (Y mm)
2.4 (3.8)
3.0 (4.8)
5.0 (8.0)
6.4 (10.0)
Carrier card
X
X
3
Clearance (X mm)
2.0
2.6
4.0
4.0
Expansion card
Y

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cisco7204Cisco7206-dcCisco7204-dc

Table of Contents