3.12 WIRING DIAGRAM—MFV, AIR-COOLED INTEGRAL DRYER
COMP
1MOL
COMPRESSOR OVERLOAD
1M
COMPRESSOR STARTER
2MOL
FAN MOTOR OVERLOAD
P1
WET SUMP PRESSURE SENSOR
P2
PACKAGE DISCHARGE PRESSURE SENSOR
T1
UNIT DISCHARGE TEMPERATURE PROBE
T3
DRYER DEWPOINT TEMPERATURE PROBE
PSW1
(OPT'L)INLET AIR FILTER SWITCH 558.9 MM WC - 22 IN WC
DPSW1
(OPT'L)OIL FILTER DIFF PRESS SWITCH 20PSID
INPUT 7 REMOTE RUN/UNLOAD
INPUT 8 CUSTOMER FURNISHED FAULT
INPUT 9 CUSTOMER FURNISHED WARNING
SOL1
LOAD CONTROL SOLENOID VALVE
SOL4
SEQUENCEING SOLENOID VALVE
SOL5
ELECTRIC CONDENSATE DRAIN VALVE
PS
24VDC POWER SUPPLY
K1
INTERNAL RUN RELAY CONTACT
K2
INTERNAL Y-DELTA START RELAY
K3
INTERNAL WYE-DELTA RUN RELAY
K4
INTERNAL LOAD CONTROL RELAY
K5
INTERNAL SEQUENCE RELAY
K6
INTERNAL ELECTRIC DRAIN RELAY
K7
INTERNAL COMMON FAULT RELAY
PMR
OPT'L POWER MONITOR RELAY
PF CAP
POWER FACTOR CORRECTION CAPACITOR (OPT'L)
HTR1
(OPT'L) SUMP HEATER 800W
HTR2
(OPT'L) HEAT TRACE
HTR3
(OPT'L) TRAP HEATER 70WATTS
HTR4
(OPT'L) CONTROL PANEL HEATER 50WATTS
TH
THERMOSTAT FOR HEAT TRACE OPTION
DESCRIPTION
COMP
3FU
FAN MOTOR BRANCH FUSES
6FU
INTEGRAL DRYER SECONDARY FUSE
7FU
INTEGRAL DRYER PRIMARY FUSES
PPR
POWER PRESENT RELAY OPTION
DF
DRYER FAULT
DR
DRYER START RELAY
NOTES
CUSTOMER TO FURNISH FUSED OR CIRCUIT
1
BREAKER DISCONNECT PER LOCAL CODES.
2
REMOVE JUMPER FOR AUXILLIARY E-STOP STRING
DEVICES
.
1MOL SETTING TO BE 1M FLA. PLUS 2M FLA.
3
USE ISOLATING RELAYS WITH DRY CONTACTS FOR
4
ANY OPTIONAL INPUTS TO THE WS CONTROLLER.
MOUNT THE RELAY LOCALLY IN THE STARTER BOX.