Sullair 1800 User Manual page 33

18, 22 & 30kw/25 & 30 & 40hp, industrial
Hide thumbs Also See for 1800:
Table of Contents

Advertisement

3.7
AIR-COOLED INTEGRAL DRYER, IDENTIFICATION 25-30H
Main Motor HP
25
25
30
30
NOTES:
1. ALLOW 4.00 FT. [1.25 METERS] MINIMUM CLEARANCE
AROUND MACHINE FOR ACCESS AND FREE CIRCULA-
TION
OF AIR.
2. A FOUNDATION OR MOUNTING CAPABLE OF SUPPORT-
ING
THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO
MAINTAIN
THE
COMPRESSOR
REQUIRED.
THE COMPRESSOR FRAME MUST BE LEV-
ELED AND SECURED
BETWEEN THE FRAME AND THE
FOUNDATION. NO PIPING
AT EXTERNAL CONNECTIONS.
3. ALL DIMENSIONS ARE <$t>1/2" [12.7MM].
4. RECOMMENDED INCOMING CUSTOMER POWER SUPPLY
IS
SHOWN ON DRAWING.
5. IF DUCTWORK IS TO BE INSTALLED FOR COOLING AIR,
HIGH STATIC FAN MUST BE SELECTED. MAX ALLOWABLE
ADDITIONAL STATIC PRESSURE 0.4 IN H20 WITH HIGH
STATIC FAN.
Motor Type
ODP
TEFC
ODP
TEFC
FRAME
LEVEL
IS
LOADS MUST BE PERMITTED
Weight
CFM Cooling Air
1575 LBS/714 KG
2000 CFM
1621 LBS/735 KG
2000 CFM
1584 LBS/718 KG
2000 CFM
1651 LBS/749 KG
2000 CFM
A1: SPACE REQUIRED TO OPEN DOORS
A2:SPACE REQUIRED TO OPEN STARTER PANEL
A3:CONTROLLER
A4:E-STOP
A5:AIR INLET
A6:EXHAUST AIRE OUT
A7:CONTAINMENT PAN DRAIN
A8:INCOMING CUSTOMER POWER SUPPLY 2.50 DIA. [63.5]
A9:MOISTURE DRAIN CONNECTION 1/4" NPT
A10:AIR OUT CONNECTION 1-1/2" NPT
A11:DRYER AIR INLET
A12:DRYER AIR OUTLET

Hide quick links: