Sullair 1800 User Manual page 35

18, 22 & 30kw/25 & 30 & 40hp, industrial
Hide thumbs Also See for 1800:
Table of Contents

Advertisement

3.8
AIR-COOLED INTEGRAL DRYER, IDENTIFICATION 40HP
Main Motor HP
40
40
NOTES:
1. ALLOW 4.00 FT. [1.25 METERS] MINIMUM CLEARANCE
AROUND MACHINE FOR ACCESS AND FREE CIRCULA-
TION OF AIR.
2. A FOUNDATION OR MOUNTING CAPABLE OF SUPPORT-
ING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO
MAINTAIN
THE
COMPRESSOR
REQUIRED. THE COMPRESSOR FRAME MUST BE LEV-
ELLED AND SECURED BETWEEN THE FRAME AND THE
FOUNDATION. NO PIPING LOADS MUST BE PERMITTED
AT EXTERNAL CONNECTIONS.
3. ALL DIMENSIONS ARE ±1/2" [12.7MM].
4. RECOMMENDED INCOMING CUSTOMER POWER SUPPLY
IS SHOWN ON DRAWING.
5. IF DUCTWORK IS TO BE INSTALLED FOR COOLING AIR,
HIGH STATIC FAN MUST BE SELECTED. MAX ALLOWABLE
ADDITIONAL STATIC PRESSURE 0.4 IN H20 WITH HIGH
STATIC FAN.
Motor Type
ODP
TEFC
A1: SPACE REQUIRED TO OPEN DOORS
A2: SPACE REQUIRED TO OPEN STARTER PANEL
A3: CONTROLLER
A4: E-STOP
A5: AIR INLET
FRAME
LEVEL
IS
A6: EXHAUST AIR OUT
A7: CONTAINMENT PAN DRAIN
A8: INCOMING CUSTOMER POWER SUPPLY
A9: MOISTURE DRAIN CONNECTION 1/4"-18 NPT
A10: AIR OUT CONNECTION 1-1/2" NPT
Weight
CFM Cooling Air
1757 LBS/797 KG
2900 CFM
1814 LBS/823 KG
2900 CFM
Ø2.72[69.0]