HOOKUP DIAGRAM

BATTERY
12V 4.0Ah
GELL-CELL
MAX battery charge
current is 360 mA.
Battery capacity for
emergency is at least
4 hours. Example:
Yuasa NP4-12.
UL LISTED
120 V 60Hz
TRANSFORMER
16.5 VAC 40 VA
Do not connect transformer
to receptacle controlled by a
switch. The transformer
must be UL listed and have a
restraining means.
Example: Basler Electric
BE 116240CAA-0002
TYPICAL BURGLARY
ZONE CONNECTIONS
Normally Closed
contacts
NC
End-Of-Line Resistors:
1KΩ 1/2 Watt
PGM OUTPUT RELAY
(Keypad [ ], [7])
WHT
BLK
RM-1
YEL
COM
Control Panel is suitable for the following
UL installations:
Household Fire and Grade A Household
Burglary
Grade A Local
Grade B Central Station and Grade A
Police Connect with basic line security
Grade C Central Station and Grade A
Poice Connect with basic line security
Refer to this manual
RED
BLK
EEPROM RESET
BATT
5 AMP
SW
AC
AUX GND
AUX
BELL
+11V
SWITCHED
- AUX
+11V
NOTES
Security detection devices that require
power from the control panel must be
Normally Open
UL listed for the intended application
contacts
and operate over the range of 10.0 to
14.0 V
. The DSC BRAVO Series is
DC
a recommended UL listed motion
detector.
All voltage outputs are rated 11V
unregulated.
Temperature Range:
0°C-49°C (32°F-120°F)
NO
Maximum Humidity:
Incorrect connections may result in
blown fuses or improper operation.
Check wiring before applying power.
GROUND START
CIRCUIT
PGM
+AUX
WHT
RED
RM-1
GRN
NC NO
* Not allowed for UL Installations.
1. Refer to instruction manual 29000124 for complete operating instructions.
2. The PC2550 is UL listed for limited energy installations per NEC article 760.
3. This equipment should be installed in accordance with National Fire
4. Do not replace fuses with a higher value than shown on this drawing.
WWW.DIYALARMFORUM.COM
NO
AUX
50 mA MAX
PC2550RK Keypad
(3 MAX)
Refer to this manual for detailed
BELL / SIREN
instructions on keypad wiring.
700 mA MAX
AUXILIARY
SUPPLY
OUTPUTS
MAX
400 mA
TYPICAL FIRE ALARM
ZONE CONNECTIONS
It is mandatory to use one UL listed indoor alarm
signaling appliance with minimum 85dB rating and a
current rating of 700 mA or less. Example: Wheelock
model 34T-12-R.
DC
AUX GND
85% R.H.
WARNING
PGM
+AUX
BLK
RED
NOTE: Smoke detector must be latching type
(Example: ESL model 445C)
To reset smoke detectors - press [ ]
then hold down key [4] for 2-3 sec.
GRN
RNG
Recognized limited energy cable should be used. Observe NEC wiring
requirements and local codes as defined by the authority having jurisdiction.
Protection Association Standard #74 (N.F.P.A. Batterymarch Park, Quincy
MA. 02269)
37
RJ31X
BRN
T-1
GRY
R-1
GRN
TIP
RED
RNG
GND
Nut
Washer
Cabinet
Bolt
Ground
Rod
SW
FIRE
AUX BELL
Bell Loop 700 mA MAX
BELL
4-wire Smoke
Alarm Initiating Loop
Detector Power
Resistance 100Ω MAX
11 V
DC
In
Out
RED
Alarm
Contact
BLK
In
Out
UL LISTED
End-Of-Line Resistor
4-wire Smoke Detector
EOLR-1
Smoke Detector Power
Supervision Relay (DSC RM-1)
12V
35mA
DC
WHT
GRN

Advertisement

loading

This manual is also suitable for:

Pc2550rk