Connecting
5.3 100 to 240 VAC power supply
Pin assignment of the X3 plug on the rear
Connector X3 is located on the back of the PS598-1. Connector X3 is intended only to
connect the PS598-1 directly to SCALANCE XR-528-6M and SCALANCE XR552-12M.
Figure 5-6
Contact
L
L
L
M
M
M
One PS598-1 per device, no redundancy
Figure 5-7
Connect the IE switch and the PS598-1 with one cable for 24 VDC and a cable for ground.
As an alternative, you can also mount the PS598-1 on the rear of the IE switch and secure it
with screws. In this case, no extra cables are necessary. You will find detailed information in
the section "Installation (Page 29)".
54
Position of the plug X3 on the PS598-1 power supply unit
Connecting a power supply unit to a SCALANCE XR552-12M. SCALANCE XR528-6M is
used analogously.
Assignment
+24 VDC
Ground
Operating Instructions, 05/2014, A5E03275845-05
SCALANCE XR-500