Chapter 4
[oE-35]~[oE-49]
P1-AG Window comparators output condition
Code/Name
oE-35
[Ai4] Max-limit level
oE-36
[Ai4] Min-limit level
oE-37
[Ai4] Hysteresis width
oE-38
[Ai5] Max-limit level
oE-39
[Ai5] Min-limit level
oE-40
[Ai5] Hysteresis width
oE-41
[Ai6] Max-limit level
oE-42
[Ai6] Min-limit level
oE-43
[Ai6] Hysteresis width
oE-44
[Ai4] Operation level
oE-45
[Ai4] Level enable
oE-46
[Ai5] Operation level
oE-47
[Ai5] Level enable
oE-48
[Ai6] Operation level
oE-49
[Ai6] Level enable
・Outputs a signal whenever the analogue input value is
within or out of range.
・As for disconnection detection, if it is in the case of
within or out of the range, a value can be set for the
operation command.
Initial
Range (unit)
value
100
-100~100(%)
-100~100(%)
-100
0
0~10(%)
0~100(%)
100
0
0~100(%)
0~10(%)
0
0~100(%)
100
0
0~100(%)
0~10(%)
0
0
-100~100(%)
00(Disable)/
00
01(Out of range)/
02(Inside range)
0~100(%)
0
00(Disable)/
00
01(Out of range)/
02(Inside range)
0~100(%)
0
00(Disable)/
00
01(Out of range)/
02(Inside range)
4-54
For parameter configuration
[oE-50]~[oE-70]
P1-AG Optional analogue output adjustment
Code/Name
oE-50
[EAo1] output terminal
oE-51
[EAo2] output terminal
oE-52
[EAo3] output terminal
oE-56
Time constant of [EAo1] filter
oE-57
[EAo1] output data type selection
oE-58
[EAo1] bias
oE-59
[EAo1] gain
oE-60
Output level when
[EAo1] adjustment mode
oE-61
Time constant of [EAo2] filter
oE-62
[EAo2] output data type selection
oE-63
[EAo2] Bias
oE-64
[EAo2] Gain
oE-65
Output level when
[EAo2] adjustment mode
oE-66
Time constant of [EAo3] filter
oE-67
[EAo3] output data type selection
oE-68
[EAo3] Bias
oE-69
[EAo3] Gain
oE-70
Output level when
[EAo3] adjustment mode
・Regarding the adjustment method of the analogue
output, please refer to the chapter 3 example of I/O
terminals adjustment.
Initial
Range (unit)
value
dA-01
Set monitor code
dA-01
dA-01
10
1~500(ms)
00(Absolute value)/
00
01(Signed value)
100.0
-100.0~100.0(%)
-1000.0~1000.0(%)
100.0
0.0~300.0(%)
100.0
1~500(ms)
10
00(Absolute value)/
00
01(Signed value)
-100.0~100.0(%)
100.0
100.0
-1000.0~1000.0(%)
100.0
0.0~300.0(%)
10
1~500(ms)
00(Absolute value)/
00
01(Signed value)
-100.0~100.0(%)
100.0
-1000.0~1000.0(%)
100.0
0.0~300.0(%)
100.0