Download Print this page

Product Overview - Chauvet Geyser P7 Quick Reference Manual

Hide thumbs Also See for Geyser P7:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Product Overview

Penta-color LEDs
LED
Display
Zone 2
Menu
Buttons
Controller
DMX In/Out
In
(3- and 5-pin)
FCQ (Fog Cleaner Quart) was specifically developed by Chauvet to clean your Geyser P7. Make
sure you use FCQ regularly, no longer than 90 days between cleanings, to increase the life of
your product.
While operating the Geyser P7, make sure there is adequate fog fluid in the machine to prevent
pump and heater damage. When the fog fluid level becomes low, simply add more fog fluid to
continue using the Geyser P7.
AC Power
This product has a fixed voltage power supply and it can work with an input voltage of either 120 VAC, 60 Hz or 230 VAC,
50 Hz, depending on the specific model.
To eliminate wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
Fuse Replacement
1.
Disconnect the product from power.
2.
Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3.
Pry the safety cap out of the housing.
4.
Remove the blown fuse from the clip on the front of the safety cap and replace with a fuse of the exact same
type and rating.
5.
Re-insert the fuse holder and reconnect power.
Geyser P7 QRG Rev. 1
QUICK REFERENCE GUIDE
Zone 1
Nozzle
Power
Power
Switch
Fuse
In
Holder
Removable Shield
Fluid Tank
Carry
Handle
Fan
Safety
Loop
Fluid
Level
Indicator
Rubber Feet for
Surface Mounting
(x4)
EN
2

Advertisement

loading