2-1. Preparations

2-1-1. Required Equipment

. Oscilloscope
Tektronix 2465 or equivalent
(bandwidth: 350 MHz or more)
. NTSC, PAL, SECAM component signal generator
Tektronix TG2000 + AVG1 (optional module) + AWVG1
(optional module) or equivalent
. VG (Programmable video signal generator)
VG854 or equivalent
. Digital voltmeter
Advantest TR6845 or equivalent
. Luminance meter
. Chrominance difference gauge
n
Perform the following adjustments at least 5 minutes after
turning on the power.
VPL-HS60/HS51A
Section 2

Electrical Adjustments

2-1-2. Factory Mode Setting

1. Press the "Setup" key on the MENU.
The "Setup" menu is displayed.
2. Set the "Status" item to "On".
3. Exit the menu.
4. Press the keys in the following order:
"ENTER" → "ENTER" → "LEFT" → "ENTER"
5. The message "Do you wish to enter into the
FACTORY MODE? Yes:↑ No:↓ " will be displayed.
6. Select "Yes:↑".
m
. When returning to the USER MODE, perform item 3.
"Do you wish to return to the USER MODE? Yes:↑
No:↓ " will be displayed. Select "Yes:↑".
. Adjustable items (W/B and Device Adjust) of the factory
mode are memorized into the NVM by the memory
operation. At the same time, the factory preset (adjusted)
data are all eliminated from the memory.
After the unit enters and then exits the GAMMA
ADJUSTMENT MODE, be sure to perform "Save to
memory". If a value is changed in the GAMMA
ADJUSTMENT MODE and the original value cannot be
restored, power off the unit and then power on again. If
the Advance Iris mode in "Cinema Black Pro" of
"Picture Adjust" is changed without performing "Save to
memory" the UF data remains unchanged. Further, if
"Save to memory" is performed then, the UF data
provided for each Iris mode is overwritten and lost.
2-2. V COM Adjustment
1. Input the green-only XGA 1 Lime ON/OFF signal to
INPUT-A, and set the CONTRAST to 70.
2. Set the screen to G VCOM adjustment of "Device
Adjust."
3. Adjust the G VCOM so that the flicker on the screen is
minimum.
4. Change the input signal to the red-only and blue-only
1 line ON/OFF signal respectively and adjust R
VCOM and B VCOM respectively so that the flicker
becomes minimum as described in step 3.
5. Save the value adjusted.
6. Set the "Image Flip" to either "V" or "HV".
7. Input the R/G/B value adjusted as above step 5.
8. Save the value adjusted.
9. Set the "Image Flip" to "OFF".