A12
Error Message
A13
Current (Sub) Menu Option
A14
Menu Number Indicator
A15
Calibration Stage
A16
Process Status
A17
Device ID / Required RPM
Note: Display fields can show different data for different calibration procedures or for different stages
in a calibration procedure.
Tilt Sensor Calibration
The C01 option in the Power Calibration submenu lets you do the Tilt Sensor Calibration. After you go to the C01 option and push
the Backlight button, the console does a check of the Power Sensor to get the calibration status and requirements.
Tilt Sensor Calibration has 3 stages: Stage 1 (Full Up Position – "UP"), Stage 2 (Full Down Position – "dn") and Stage 0 (Zero G
Calibration – "0G"). The Tilt Calibration sub-submenu options are UP, dn, 0G and "– –" (exit).
NOTICE:
When you do the initial installation of the Power Sensor, do the Full Up Position calibration and Full Down Position
calibration. Do not do Zero G Calibration for a new Power Sensor (fresh out of the box). Zero G Calibration is
done at the factory.
If you move the bike after Tilt Sensor Calibration is done, do the Full Up Position calibration and Full Down Position
calibration again to correct errors caused by differences in the floor level.
• • •
Tap the AVG/END or STAGE button to look at the Stage options.
• • •
Push the Backlight button to make your selection.
Note:
To stop the calibration at any point, push and hold the AVG/END button for 3 seconds.
A18
Required Angle
A19
Countdown Timer
A20
Calibration Stage Indicator
A21
Current Angle
A49
Current RPM
15 15 15