4.2 Electrical connection

For models with a water softener
an 'approved' double check valve or some other no less effective device providing backflow prevention
protection to at least fluid category two shall be fitted at the point of connection between the water supply
and the fitting or appliance.
For models without a water softener
an 'approved' single check valve or some other no less effective device providing backflow prevention
protection to at least fluid category two shall be fitted at the point of connection between the water supply
and the fitting or appliance.
The dishwasher and any additional equipment must be connected to the electrical system by authorised,
skilled staff, in accordance with the relevant regulations; also comply with the technical instructions for the
connection. The total rated power is stated on the appliance's technical data plate. The electrical protection
devices fitted for the dishwasher must serve this appliance only. The user must have a master switch and a
differential safety breaker, with rating suitable for the appliance's characteristics, installed on the electricity
supply line in accordance with the relevant regulations. These switches must be installed close to the
dishwasher, be easily accessible after installation, and provide complete disconnection from the electrical
mains in overvoltage class III conditions.
Warning!
The dishwasher is always powered up unless the master switch is turned off.
Connect the appliance to the user's earth system. The
hand corner of the appliance. The earth wire (PE) is yellow-green in color, the neutral wire (N) is blue and the
live wires (L1, L2, L3) are black, grey and brown. In the event of single-phase connection (230V-1N~), the
connection to the electrical mains must be made using a cable with plug compliant with the relevant
regulations.
THE POWER SUPPLY CABLE, IF FITTED, MUST BE REPLACED BY THE MANUFACTURER OR AN AUTHORISED
SERVICE CENTRE IN ACCORDANCE WITH THE TECHNICAL DATA SPECIFIED ON THE WIRING DIAGRAM
SUPPLIED WITH THE APPLIANCE, TO PREVENT ALL RISKS.

5 FIRST START-UP

First start-up
The electrical protection system must undergo a functional test before the appliance is put into operation.
The appliance must be installed and/or inspected by qualified staff, who will start it up for the first time and provide the
relevant operating instructions.
Preparing for use (important)
The rinse aid dispenser is fitted on all models, the detergent dispenser only on some.
If both dispensers are present put the external detergent and rinse aid containers in place and insert the respective intake
hoses on the rear of the appliance into them. Red hose: detergent, blue hose: rinse aid
Before inserting the hoses into the containers, fit the weights (needed to ensure that they always draw in
liquid from the bottoms of the containers) and the filters onto their ends as shown. If the detergent dispenser
is not factory-fitted, it can be retrofitted after ordering the relative kit.
As an alternative an external dispenser can be fitted, making the electrical connection by means of an H05 RN -F 2x0.5 mm
electrical cable, which can be laid along the route shown in the TECHNICAL DATA diagram and connected as shown i n the wiring
diagram supplied with the dishwasher. The dispenser must operate on 230V/50 Hz with maximum power absorption of 15 W.
Connect to the detergent dispenser outside the dishwasher using the red hose mentioned above.
CWC 611
terminal for the connection is in the bottom right-
6