York ZF036 Installation Manual page 4

Zf series
Hide thumbs Also See for ZF036:
Table of Contents

Advertisement

826081-XIM-C-0214
Before performing service or maintenance operations on
unit, turn off main power switch to unit. Electrical shock
could cause personal injury. Improper installation,
adjustment, alteration, service or maintenance can
cause injury or property damage. Refer to this manual.
For assistance or additional information consult a
qualified installer, service agency or the gas supplier.
This system uses R-410A Refrigerant which operates at
higher pressures than R-22. No other refrigerant may be
used in this system. Gage sets, hoses, refrigerant
containers and recovery systems must be designed to
handle R-410A. If you are unsure, consult the equipment
manufacturer. Failure to use R-410A compatible servicing
equipment may result in property damage or injury.
If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage,
personal injury or loss of life.
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
a. Do not try to light any appliance.
b. Do not touch any electrical switch; do not use any
phone in your building.
c. Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
d. If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Due to system pressure, moving parts, and electrical
components, installation and servicing of air conditioning
equipment can be hazardous. Only qualified, trained service
personnel should install, repair, or service this equipment.
Untrained personnel can perform basic maintenance functions
of cleaning coils and filters and replacing filters.
4
Observe all precautions in the literature, labels, and tags
accompanying the equipment whenever working on air
conditioning equipment. Be sure to follow all other applicable
safety precautions and codes including ANSI Z223.1 or CSA-
B149.1- latest edition.
Wear safety glasses and work gloves. Use quenching cloth and
have a fire extinguisher available during brazing operations.
This product must be installed in strict compliance with
the enclosed installation instructions and any applicable
local, state and national codes including, but not limited
to, building, electrical, and mechanical codes.
The furnace and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing at pressures in excess of 1/2 PSIG.
Pressures greater than 1/2 PSIG will cause gas valve
damage resulting in a hazardous condition. If it is
subjected to a pressure greater than 1/2 PSIG, the gas
valve must be replaced.
The furnace must be isolated from the gas supply piping
system by closing its individual manual shut-off valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 PSIG.
Reference
Additional information on the design, installation, opera-
tion and service of this equipment is available in the fol-
lowing reference forms:
• 826081 -General Installation
• 035-19404-000 -Economizer Accessory
• 530.18-N1.13V -Man. Outdoor Air Damper Accessory 0 -
35%
• 530.18-N1.14V -Man. Outdoor Air Damper Accy 0 - 100%
• 035-07364-000 -Motorized Outdoor Air Damper Accy.
• 253431 -Low NOx Accessory
• 11031 -High Altitude Accy. (Natural Gas)
• 11032 -High Altitude Accy. (Propane)
• 035-12566-000 -Gas Piping Accessory
• 530.46-N1.29V -Propane Conversion Accessory
• 035-19422-000 –Electric Heat Accessory
• 035-19405-000 -Barometric Relief Damper
• 530.46-N1.1V -Dual Enthalpy Accessory
• 530.18-N1.10V -Power Exhaust Accessory
Johnson Controls Unitary Products

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zf048Zf060Zf076

Table of Contents