Brew Unit Drive, Home Position; Figure 030-4: Selectable Volume Areas 1, 2 And 3; Figure 030-5: Home Position, Rear View; Figure 030-6: Home Position, Front View - Miele CVA 4062 Technical Information

Coffee systems cva 406 series
Table of Contents

Advertisement

Technical Information

Figure 030-4: Selectable Volume Areas 1, 2 and 3

If the measure quantity varies from the set quantity, then the grinding time will be
increased or decreased by approximately 0.2 seconds as appropriate during the next
grinding cycle. Because the maximum ground quantity compensation is ±1.6 seconds,
this adjustment can be repeated up to 8 times.
2.1.3

Brew Unit Drive, Home Position

If the brew unit is in the home position, the left cam of the double-cam element
activates the top microswitch; the bottom microswitch is not switched (Figure 030-5).
The pawl is in the home position (Figure 030-6).

Figure 030-5: Home Position, Rear View

Figure 030-6: Home Position, Front View

CVA 4062/CVA 4066/CVA 4068 Coffee Systems
38