Communications Specifications - Omron E5CN-HR2M-500 Manual

E5cn-h series. advanced digital temperature controller. logic operations and preventive maintenance function.
Hide thumbs Also See for E5CN-HR2M-500:
Table of Contents

Advertisement

USB-Serial Conversion Cable
Applicable OS
Applicable software
Applicable models
USB interface standard
DTE speed
Connector specifications
Power supply
Power supply voltage
Current consumption
Ambient operating
temperature
Ambient operating humidity 10% to 80%
Storage temperature
Storage humidity
Altitude
Weight
Note: A driver must be installed in the personal computer. Refer to
installation information in the operation manual for the
Conversion Cable.

Communications Specifications

Transmission line
RS-485: Multipoint
connection method
RS-232C: Point-to-point
Communications
RS-485 (two-wire, half duplex)/RS-232C
Synchronization
Start-stop synchronization
method
Protocol
CompoWay/F, SYSWAY, or Modbus
1200, 2400, 4800, 9600, 19200, 38400, or
Baud rate
57600 bps
ASCII (CompoWay/F, SYSWAY)
Transmission code
RTU (Modbus)
Data bit length *
7 or 8 bits
Stop bit length *
1 or 2 bits
Vertical parity (none, even, odd)
Frame check sequence (FCS) with SYSWAY
Error detection
Block check character (BCC) with
CompoWay/F or CRC-16 Modbus
Flow control
None
Interface
RS-485, RS-232C
Retry function
None
Communications
217 bytes
buffer
Communications
0 to 99 ms
response wait time
Default: 20 ms
* The baud rate, data bit length, stop bit length, and vertical parity can
be individually set using the Communications Setting Level.
Buy Now: www.ValinOnline.com | Phone: 800-774-5630 | Email: CustomerService@valin.com
Windows XP/Vista/7/8
CX-Thermo version 4 or higher
E5AN/E5EN/E5CN/E5CN-U/
E5AN-H/E5EN-H/E5CN-H
Conforms to USB Specification 1.1.
38400 bps
Computer: USB (type A plug)
Temperature Controller: Setup Tool
port (on bottom of Controller)
Bus power (Supplied from USB
host controller.)
5 VDC
70 mA
0 to 55°C (with no condensation or
icing)
−20 to 60°C (with no condensation
or icing)
10% to 80%
2,000 m max.
Approx. 100 g
Current Transformer (Order Separately)
Ratings
Dielectric strength
Vibration resistance
Weight
Accessories (E54-CT3 only)
Heater Burnout Alarms, SSR Failure
Alarms, and Heater Overcurrent Alarms
Models with detection for single-
phase heaters: One input
CT input (for heater
Models with detection for single-
current detection)
phase or three-phase heaters: Two
inputs
Maximum heater current
50 A AC
Input current indication
±5% FS ±1 digit max.
accuracy
Heater burnout alarm
0.1 to 49.9 A (in units of 0.1 A)
setting range *1
Minimum detection ON time: 100 ms
SSR failure alarm setting
0.1 to 49.9 A (in units of 0.1 A)
range *2
Minimum detection OFF time: 100 ms
Heater overcurrent alarm
0.1 to 49.9 A (in units of 0.1 A)
setting range *3
Minimum detection ON time: 100 ms
*1. For heater burnout alarms, the heater current will be measured
when the control output is ON, and the output assigned to the
alarm 1 function will turn ON if the heater current is lower than the
set value (i.e., heater burnout detection current value).
*2. For SSR failure alarms, the heater current will be measured when
the control output is OFF, and the output assigned to the alarm 1
function will turn ON if the heater current is higher than the set
value (i.e., SSR failure detection current value).
*3. For heater overcurrent alarms, the heater current will be
measured when the control output is ON, and the output assigned
to the alarm 1 function will turn ON if the heater current is higher
than the set value (i.e., heater overcurrent detection current
value).
Electrical Life Expectancy Curve for
Relays (Reference Values)
500
300
100
50
30
10
5
E5CN-H
250 VAC, 30 VDC
3
(resistive load)
cosφ = 1
1
0
1
2
3
4
Switching current (A)
E5CN-H
1,000 VAC for 1 min
2
50 Hz, 98 m/s
E54-CT1: Approx. 11.5 g,
E54-CT3: Approx. 50 g
Armatures (2)
Plugs (2)
5
6
8

Hide quick links:

Advertisement

Table of Contents