Physical specifications
The SR530 server has the following dimensions and weight (approximate):
Height: 43 mm (1.7 in)
Width: 434 mm (17.1 in)
Depth: 715 mm (28.1 in)
Weight:
Minimum configuration: 10.2 kg (22.5 lb)
Maximum configuration: 16.0 kg (35.3 lb)

Operating environment

The SR530 server complies with ASHRAE class A2 specifications. The server performance might be impacted
when the operating temperature is outside the ASHRAE A2 specifications. Depending on the hardware
configuration, some server models comply with ASHRAE class A3 and class A4 specifications. To comply
with ASHRAE class A3 and class A4 specifications, the server models must meet the following hardware
configuration requirements at the same time:
Two power supplies must be installed
No system fan fails
The SR530 server is supported in the following environment:
Air temperature:
Operating:
ASHRAE Class A4: 5 °C - 45 °C (41 °F - 113 °F); for altitudes above 900 m (2,953 ft),
decrease the maximum ambient temperature by 1 °C for every 125-m (410-ft) increase in
altitude
ASHRAE Class A3: 5 °C - 40 °C (41 °F - 104 °F); for altitudes above 900 m (2,953 ft),
decrease the maximum ambient temperature by 1 °C for every 175-m (574-ft) increase in
altitude
ASHRAE Class A2: 10 °C - 35 °C (50 °F - 95 °F); for altitudes above 900 m (2,953 ft),
decrease the maximum ambient temperature by 1 °C for every 300-m (984-ft) increase in
altitude
Non-operating: 5 °C - 45 °C (41 °F - 113 °F)
Storage: -40 °C - +60 °C (-40 °F - 140 °F)
Maximum altitude: 3,050 m (10,000 ft)
Humidity:
Operating:
ASHRAE Class A4: 8% - 90% (non-condensing); maximum dew point: 24 °C (75 °F)
ASHRAE Class A3: 8% - 85% (non-condensing); maximum dew point: 24 °C (75 °F)
ASHRAE Class A2: 8% - 80% (non-condensing); maximum dew point: 21 °C (70 °F)
Storage: 8% - 90% (non-condensing)
Electrical:
100 - 127 (nominal) V AC; 50 Hz / 60 Hz
200 - 240 (nominal) V AC; 50 Hz / 60 Hz
180 - 300 V DC (supported in China only)
Acoustics:
Minimum configuration:
Operating: 5.6 bels
Idle: 4.9 bels
Maximum configuration:
Operating: 6.5 bels
Idle: 6.1 bels