Virtual time response
Scaling factor
Using a scaling factor, you can speed up or slow down the virtual clock of the virtual
controller for simulations.
● The default is 1, i.e. the course of the virtual time corresponds to the course of real time.
● Fast forward: A scaling factor greater than 1 accelerates the virtual clock.
Example: Scaling factor 2.0 → The virtual time is running twice as fast.
● Slow motion: A scaling factor less than 1 decelerates the virtual clock.
Example: Scaling factor 0.5 → The progress of the virtual time slows down to 50%.
API functions
● GetScaleFactor() (Page 221)
● SetScaleFactor() (Page 222)
● ScaleFactor { get; set; } (Page 223)
See also
Settings for the virtual time (Page 220)
74
S7-PLCSIM Advanced
Function Manual, 12/2017, A5E37039512-AB