Application Planning; Alternative Emc Cable Glands; Selection Of Suitable Cables - Siemens SIWAREX JB Compact Operating Instructions

Stainless steel with atex certificate
Hide thumbs Also See for SIWAREX JB:
Table of Contents

Advertisement

Application planning

4.1

Alternative EMC cable glands

If you need stainless steel EMC cable glands, you can purchase them from corresponding
suppliers. Please note that the cable glands must be approved for the respective
applications. See Service and support
(http://www.siemens.com/automation/service&support)
Note
Further information can be found under Ordering data (Page 22)
4.2

Selection of suitable cables

Signal cable
The junction box is connected to the weighing module by means of a signal cable. Use a
shielded cable with six cores as the signal cable. We recommend the SIWAREX cable
Li2Y2x0.75St+2x(2x0.34St)-CY:
● For standard applications: 7MH4702-8AG, orange sheath color.
● For intrinsically safe Ex applications: 7MH4702-8AF, light blue sheath color.
The cables and lines must correspond to the installation regulations according to EN 60079-
14. In hazardous areas, the diameter of individual conductors must not be smaller than 0.1
mm.
Short circuit/explosion hazard
At an ambient temperature T ≥ 60 °C, use heat-resistant cables which are approved for an
ambient temperature at least 20 K higher.
Note
The maximum cable length between the load cell and the weighing module is stated in the
weighing module documentation.
10
WARNING
SIWAREX JB stainless steel with ATEX certificate
Compact Operating Instructions, 06/2010, A5E01257284C-01
4

Advertisement