Check that the slide switch [SW1] is on the SINK
3
side.
If it is set to PLC/SOURCE side, set it to the SINK
side.
For details of the slide switch, refer to [2. 3. 5].
4
Check connection of the terminals to be used on the
control terminal block.
For details of positions of the control terminal block
and terminals, refer to [2. 3. 5].
Digital input terminals [F], [CC]
• Connect the switch and execute forward run of the
motor.
Digital input terminals [S1], [CC]
• Connect relay 1 to perform preset speed operation.
Digital input terminals [S2], [CC]
• Connect relay 2 to perform preset speed operation.
• With combination of relay 1 ON, relay 2 ON, and both relay 1 and relay 2 ON, you can set three
Memo
types of frequency command values.
5
Mount the covers.
For how to mount them, refer to [2. 2].
6
Turn on the power of the inverter.
7
Switch to [Setting mode].
8
Select "4. Basic parameter" and press the [OK] key.
The basic parameter screen is displayed.
Connect switches
4-39
4. [Basic operation] Operation methods of motor
E6582062