Displaying Calibration Values 16.6 - HEIDENHAIN TNC 320 User's Manual For Cycle Programming

Hide thumbs Also See for TNC 320:
Table of Contents

Advertisement

16.6
Displaying calibration values
The TNC saves the effective length and effective radius of the
touch probe in the tool table. The TNC saves the ball-tip center
offset of the touch probe in the touch-probe table in the CAL_OF1
(principal axis) and CAL_OF2 (secondary axis) columns. You can
display the values on the screen by pressing the TOUCH PROBE
TABLE soft key.
A measuring log is created automatically during calibration. The
log file is named TCHPRAUTO.html. This file is stored in the same
location as the original file. The measuring log can be displayed in
the browser on the control. If a program uses more than one cycle
to calibrate the touch probe, TCHPRAUTO.html will contain all the
measuring logs. When running a touch probe cycle in the Manual
Operation mode, the TNC saves the measuring log under the name
TCHPRMAN.html. This file is stored in the folder TNC: \ *.
Please make sure the correct tool number is active
when you use the touch probe system. Regardless
of whether you want to use a touch probe cycle in
automatic mode or Manual operation mode.
For more information, see Chapter Touch probe table
HEIDENHAIN | TNC 320 | User's manual for cycle programming | 9/2016

Displaying calibration values 16.6

16
431

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 320 programming station

Table of Contents