HP 81101A Reference Manual page 72

50 mhz
Hide thumbs Also See for 81101A:
Table of Contents

Advertisement

Programming Reference
SCPI Instrument Command List
Command
:VOLT[1]:HIGH
Long
[:SOURce]:VOLTage[1][:LEVel][:IMMediate]:HIGH
Form
Set & Query
Parameter
Numeric
Parameter suffix
V with engineering prefixes.
Value coupling
Range coupling
With low level, see
*RST value
500 mV
–9.9 V to 10.0 V (50 Ω into 50 Ω)
Specified limits
Description
Use this command to program the high level voltage of the OUTPUT
signal. Note that to set the OUTPUT levels in terms of voltage, you first
have to execute the [:SOURce]:HOLD VOLTage command to enable the
[:SOURce]:VOLTage subsystem.
The available voltage range is limited by the combination of:
• Specified current limits
• Actual OUTPUT impedance setting :OUTPut:IMPedance
• Actual expected load impedance setting
Example
To set the high level voltage:
:HOLD VOLT
:VOLT:HIGH 4.8V
72
Amplitude = High – Low
High – Low
Offset =
page 73
:OUTPut:IMPedance:EXTernal
2
Enable VOLTAGE subsystem
Set OUTPUT high level voltage to 4.8 V

Hide quick links:

Advertisement

Table of Contents
loading