3-2-2. Display of Previously Detected Error Codes
When the DSR-DR1000/DR1000P detects an internal abnormality, an error code is memorized in EE-
PROM.
A maximum of eight error codes detected previously, starting from the latest error code, can be displayed.
Displaying the Past Error Codes
1. While pressing the [&] key, press the [MENU] key.
2. Move the cursor to SERVICE SUPPORT so that the
letters are highlighted using the [(], [)] keys, then
press the [*] key.
3. Move the cursor to ERROR LOG so that the letters are
highlighted using the [(], [)] keys, then press the [*]
key.
The display changes as shown to the right, and the
error log appears.
DSR-DR1000/DR1000P
MA I NTENANCE MENU
MENU DATA CONTROL
D I SK CHECK
SERV I CE SUPPORT
OTHERS
MA I NTENANCE MENU
SERV I CE SUPPORT
ERROR LOG
D I AGNOST I CS CONTROL
MA I NTENANCE MENU
SERV I CE SUPPORT
ERROR LOG
ERROR-40-000
ERROR-91-125
ERROR-95-102
ERROR-92-101
ERROR-91-130
ERROR-95-100
3-5 (E)